Pregled bibliografske jedinice broj: 271872
Application of potential-sensitive fluorescent dyes in anion- and cation-sensitive polymer membranes
Application of potential-sensitive fluorescent dyes in anion- and cation-sensitive polymer membranes // Sensors & Actuators B-Chemical, 39 (1997), 1-3; 239-245 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 271872 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Application of potential-sensitive fluorescent dyes in anion- and cation-sensitive polymer membranes
Autori
Mohr, G.J. ; Murković, Ivana ; Lehmann, F. ; Haider, C. ; Wolfbeis, O.S.
Izvornik
Sensors & Actuators B-Chemical (0925-4005) 39
(1997), 1-3;
239-245
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
optodes; nitrate sensors; nitrite sensors; potassium sensors; mercury sensors; fluorescence; polarity probes
Sažetak
The applicability of two potential-sensitive dyes (PSDs) for optical sensing of ions is reported. In particular, nitrate-and nitrite-responsive as well as potassium-and mercury-sensitive polymer membranes have been developed. In general, membranes are composed of a plasticized polymer, an ion carrier and a fluorescent dye which optically transduces the extraction of the analyte ion in the polymer matrix. The nitrate sensor membrane is composed of rhodamine B octadecylester and the anion-exchange catalyst is tridodecylmethylammonium chloride. Both are dissolved in plasticized PVC. The nitrite sensor is based on the same dye and the same polymer matrix but with benzyl-bis(triphenylphosphine) palladium(II) chloride acting as the nitrite-selective carrier. The potassium sensor membrane consists of the carbocyanine dye DiOC16(3), valinomycin and a lipophilic berate salt. The mercury 'sensor' is based on the irreversible decomposition of berate by mercury ions and is composed of DiOC16(3) and berate only. All sensor membranes have been investigated in terms of signal change, sensitivity, stability, limits of detection and the selectivity for the analyte over interferent ions. The mechanism of the sensor membranes is discussed on the basis of changes of the microenvironment of solvatochromic dyes, which result in analyte-dependent signal changes.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Ustanove:
Fakultet kemijskog inženjerstva i tehnologije, Zagreb
Profili:
Ivana Steinberg
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus