Pregled bibliografske jedinice broj: 26897
An improvement of electrical motor insulation condition testing
An improvement of electrical motor insulation condition testing // Proceedings of the 10th EDPE Conference
Dubrovnik, Hrvatska, 1998. str. 56-62 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 26897 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
An improvement of electrical motor insulation condition testing
Autori
Ban, Drago ; Cettolo, Mirko ; Miletić, Boris
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 10th EDPE Conference
/ - , 1998, 56-62
Skup
10th EDPE Conference
Mjesto i datum
Dubrovnik, Hrvatska, 14.10.1998. - 16.10.1998
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
electrical motor; insulation; condition testing
Sažetak
This paper presents one of the maintenance test methods and the results of its application in the determination of the insulation condition of high-voltage electric motors. Testing and data processing were carried out on site using a PC and adequate software. Automatization eases and speeds the testing and the interpretation of results. This method is a modification of the Höfler method. Highly stabilized dc voltage is applied to the motor windings in 5 steps, from 0.3 Un to 1.5 Un, in steps of 0.3 Un, while at the same time the leakage currents are being measured. In the case of "ideal insulation", leakage currents are proportional to the applied dc voltage, i.e. the insulation resistance is independent of the applied voltage. In reality, insulation resistance and leakage currents depend on the applied voltage. The ways the leakage current depends on voltage and its magnitude can be used to determine the insulation condition. The insulation condition is estimated based on the non-linearity coefficients value.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika