Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 26600

The importance of jugular bulb oximetry for appropriate setting of ventilator in patients with severe head injury


Ščap, Miroslav; Kukin, Tomislav; Sekulić, Ante; Ključar, Ivo
The importance of jugular bulb oximetry for appropriate setting of ventilator in patients with severe head injury, 1998. (ostali članci/prilozi).


CROSBI ID: 26600 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The importance of jugular bulb oximetry for appropriate setting of ventilator in patients with severe head injury

Autori
Ščap, Miroslav ; Kukin, Tomislav ; Sekulić, Ante ; Ključar, Ivo

Izvornik
Anestesia 2000

Vrsta, podvrsta
Ostale vrste radova, ostali članci/prilozi

Godina
1998

Ključne riječi
Severe head injury; jugular bulb oximetry; mech. ventilation

Sažetak
Mechanical hyperventilation is widely used in patients with severe head injury during last twenty years. Hyperventilation to PaCO2 of 20 mmHg showed to have detrimental effect on the outcome in one randomized trial. The use of continous jugular bulb oximetry demonstrated a great number of desaturations associated with poor outcome. In this study hypocarbia was the most common single systemic cause of desaturation. In our previous study we demonstrated that even inttermitent measurments of SjO2. resulted in better ventilator settings. The objective of this study was the evaluation of continous SjO2 monitoring on optimal ventilator setting in severe head injury patients. Methods: 17 patients with severe head injury were included in the study (Glasgow Coma Scale score 3-8). All the patients were mechanicaly hyperventilated to PaCO2 of about 30 mmHg. Continus sedation and analgesia, using midazolam and fentanyl and intermittent relaxation using pancuronium was performed. Continuous monitoring of ICP (using Leeds boult, or Codman MicroSensor ICP transducer), arterial pressure, endexpiratory CO2 and pulse oximetry (RGM 5250 Ohmeda) was starded as soon as possible. Continuous monitoring of SjO2 was performed with Opticath 4F catheter and Oximetric 3 System (Abbott). All patients included in the study had cerebral perfusion pressure of at least 60 mmHg and ICP not higher than 20 mmHg. During the monitoring no periods of hypoxia or/and anemia were recorded. Duration of SjO2 monitoring was between five and thirdteen days. Ventilator settings were ajusted in order to keep SjO2 above 55%.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
108720

Ustanove:
Medicinski fakultet, Zagreb

Profili:

Avatar Url Miroslav Ščap (autor)

Avatar Url Tomislav Kukin (autor)

Avatar Url Ivo Ključar (autor)


Citiraj ovu publikaciju:

Ščap, Miroslav; Kukin, Tomislav; Sekulić, Ante; Ključar, Ivo
The importance of jugular bulb oximetry for appropriate setting of ventilator in patients with severe head injury, 1998. (ostali članci/prilozi).
Ščap, M., Kukin, T., Sekulić, A. & Ključar, I. (1998) The importance of jugular bulb oximetry for appropriate setting of ventilator in patients with severe head injury. Anestesia 2000. Ostali članci/prilozi.
@unknown{unknown, author = {\v{S}\v{c}ap, Miroslav and Kukin, Tomislav and Sekuli\'{c}, Ante and Klju\v{c}ar, Ivo}, year = {1998}, keywords = {Severe head injury, jugular bulb oximetry, mech. ventilation}, title = {The importance of jugular bulb oximetry for appropriate setting of ventilator in patients with severe head injury}, keyword = {Severe head injury, jugular bulb oximetry, mech. ventilation} }
@unknown{unknown, author = {\v{S}\v{c}ap, Miroslav and Kukin, Tomislav and Sekuli\'{c}, Ante and Klju\v{c}ar, Ivo}, year = {1998}, keywords = {Severe head injury, jugular bulb oximetry, mech. ventilation}, title = {The importance of jugular bulb oximetry for appropriate setting of ventilator in patients with severe head injury}, keyword = {Severe head injury, jugular bulb oximetry, mech. ventilation} }




Contrast
Increase Font
Decrease Font
Dyslexic Font