The value of F-18FDG triple-haed coincidence PET in the posttreatment evaluation of patients with lymphoma


Huić, Dražen; Mutvar, Andrea; Radman, Ivo; Grošev, Darko; Labar, Boris; Žuvić, Marijan; Dodig, Damir; Aurer, Igor; Nemet, Damir
The value of F-18FDG triple-haed coincidence PET in the posttreatment evaluation of patients with lymphoma // Clinical Nuclear Medicine, 31 (2006), 275-277 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 263892 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The value of F-18FDG triple-haed coincidence PET in the posttreatment evaluation of patients with lymphoma

Autori
Huić, Dražen ; Mutvar, Andrea ; Radman, Ivo ; Grošev, Darko ; Labar, Boris ; Žuvić, Marijan ; Dodig, Damir ; Aurer, Igor ; Nemet, Damir

Izvornik
Clinical Nuclear Medicine (0363-9762) 31 (2006); 275-277

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Hodgkin’ s disease; non-Hodgkin’ s lymphoma; fluorine-18-fluorodeoxyglucose; FDG; PET; coincidence; therapy monitoring; prognosis; follow-up

Sažetak
We performed a single centre study comprised 31 consecutive patients with lymphoma within 3 months after completion of conventional initial therapy or after salvage therapy with high-dose chemotherapy. PET studies were done by using fluorine-18-fluorodeoxyglucose (FDG) and hybrid PET camera with triple head coincidence imaging capability. The long-term follow-up data (at least 12 months, median 20 months) were extracted from the patients’ medical files. Fifteen patients were FDG - negative, 12 were positive and in four patients only slightly increased FDG uptake was observed (equivocal findings – two relapsed). Besides all shortcomings of coincidence PET, we found this hybrid PET methodology good enough for reliable prognosis in follow-up of our patients, especially in those without FDG pathological fixation.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti, Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Projekti:
0108198
0214205

Ustanove:
Medicinski fakultet, Zagreb

Profili:

Avatar Url Boris Labar (autor)

Avatar Url Igor Aurer (autor)

Avatar Url Damir Dodig (autor)

Avatar Url Dražen Huić (autor)

Avatar Url Damir Nemet (autor)

Avatar Url Ivo Radman-Livaja (autor)

Avatar Url Darko Grošev (autor)


Citiraj ovu publikaciju:

Huić, Dražen; Mutvar, Andrea; Radman, Ivo; Grošev, Darko; Labar, Boris; Žuvić, Marijan; Dodig, Damir; Aurer, Igor; Nemet, Damir
The value of F-18FDG triple-haed coincidence PET in the posttreatment evaluation of patients with lymphoma // Clinical Nuclear Medicine, 31 (2006), 275-277 (međunarodna recenzija, članak, znanstveni)
Huić, D., Mutvar, A., Radman, I., Grošev, D., Labar, B., Žuvić, M., Dodig, D., Aurer, I. & Nemet, D. (2006) The value of F-18FDG triple-haed coincidence PET in the posttreatment evaluation of patients with lymphoma. Clinical Nuclear Medicine, 31, 275-277.
@article{article, author = {Hui\'{c}, Dra\v{z}en and Mutvar, Andrea and Radman, Ivo and Gro\v{s}ev, Darko and Labar, Boris and \v{Z}uvi\'{c}, Marijan and Dodig, Damir and Aurer, Igor and Nemet, Damir}, year = {2006}, pages = {275-277}, keywords = {Hodgkin and \#8217, s disease, non-Hodgkin and \#8217, s lymphoma, fluorine-18-fluorodeoxyglucose, FDG, PET, coincidence, therapy monitoring, prognosis, follow-up}, journal = {Clinical Nuclear Medicine}, volume = {31}, issn = {0363-9762}, title = {The value of F-18FDG triple-haed coincidence PET in the posttreatment evaluation of patients with lymphoma}, keyword = {Hodgkin and \#8217, s disease, non-Hodgkin and \#8217, s lymphoma, fluorine-18-fluorodeoxyglucose, FDG, PET, coincidence, therapy monitoring, prognosis, follow-up} }
@article{article, author = {Hui\'{c}, Dra\v{z}en and Mutvar, Andrea and Radman, Ivo and Gro\v{s}ev, Darko and Labar, Boris and \v{Z}uvi\'{c}, Marijan and Dodig, Damir and Aurer, Igor and Nemet, Damir}, year = {2006}, pages = {275-277}, keywords = {Hodgkin and \#8217, s disease, non-Hodgkin and \#8217, s lymphoma, fluorine-18-fluorodeoxyglucose, FDG, PET, coincidence, therapy monitoring, prognosis, follow-up}, journal = {Clinical Nuclear Medicine}, volume = {31}, issn = {0363-9762}, title = {The value of F-18FDG triple-haed coincidence PET in the posttreatment evaluation of patients with lymphoma}, keyword = {Hodgkin and \#8217, s disease, non-Hodgkin and \#8217, s lymphoma, fluorine-18-fluorodeoxyglucose, FDG, PET, coincidence, therapy monitoring, prognosis, follow-up} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • Biological Abstracts
  • Excerpta Medica
  • Index Medicus





Contrast
Increase Font
Decrease Font
Dyslexic Font