Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 263365

Dinamičko praćenje D-dimera različitim metodama za kvantitativno određivanje


Zovko, Vlasta; Coen Herak, Desiree; Živković, Marcela; Zadro, Renata
Dinamičko praćenje D-dimera različitim metodama za kvantitativno određivanje // Biochemia Medica
Poreč, Hrvatska, 2006. str. 246-247 (predavanje, domaća recenzija, sažetak, znanstveni)


CROSBI ID: 263365 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Dinamičko praćenje D-dimera različitim metodama za kvantitativno određivanje
(Dynamic D-dimer monitoring by different methods for quantitative determination)

Autori
Zovko, Vlasta ; Coen Herak, Desiree ; Živković, Marcela ; Zadro, Renata

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Biochemia Medica / - , 2006, 246-247

Skup
5. hrvatski kongres medicinskih biokemičara

Mjesto i datum
Poreč, Hrvatska, 23.10.2006. - 26.10.2006

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Domaća recenzija

Ključne riječi
D-dimeri; razgradni produkti fibrinogena/fibrina
(D-dimers; fibrinogen/fibrin degradation products)

Sažetak
Osnovni problem u danas dostupnim testovima za kvantitativno određivanje koncentracije D-dimera predstavlja različita specifi čnost svakog pojedinog testa prema razgradnim produktima umreženog fi brina i fi brinogena. Određivanjem koncentracije D-dimera kvantitativim testovima različite metodologije ispitivana je međuovisnost dobivenih koncentracija D-dimera i ukupnih razgradnih produkata fi brinogena i fi brina (TDP). Koncentracije Ddimera izmjerene su u plazmama 40 bolesnika pomoću NycoCard D-Dimer, IL Test D-Dimer, D-Dimer PLUS i STA Liatest D-DI, a koncentracije TDP-a pomoću testa Fibrinostika TDP. Rezultati su se razlikovali u 16/40 (40%) uzoraka koji su podijeljeni u 4 skupine prema rezultatima dobivenih NycoCard testom: I. <0, 3 mg/L ; II. 0, 3-0, 6 mg/L ; III. 0, 7- 1, 2 mg/L ; IV. >1, 2 mg/L. Usporedivi rezultati su dobiveni u uzorcima skupine IV. Većina rezultata je bila usporediva u skupini III, osim kod 4 negativna uzorka: 1 sa STA Liatest D-DI i 3 s IL Test D-Dimer. Najveće razlike su opažene u skupini II (9/12 uzoraka), oko granične vrijednosti za Nyco- Card. U 3/5 uzoraka s normalnim NycoCard vrijednostima (skupina I) dobiveni su pozitivni rezultati: 1 sa STA Liatest D-DI i 2 s D-Dimer PLUS testom. Usporednim određivanjem koncentracije D-dimera Nycocard testom i Vidas D-dimer testom dobivene su razlike u 10/48 uzoraka, a usporedbom IL Test D-dimer i Vidas D-dimer u 18/102 uzorka.Najveći broj rezultata odstupao je kod Nycocard vrijednosti <=0.3 mg/L (7/10) odnosno kod granične vrijednosti za IL test (16/102). U pojedinim uzorcima su Nycocard testom odnosno IL testom izmjerene izrazito visoke koncentracije D-dimera dok su Vidas testom dobivene The main problems in nowadays commercially available tests for quantitative D-dimer assays are that they display variable specifi ty toward cross-linked fi brin derivatives as well as fi brinogen degradation products.D-dimer determination with quantitative D-dimer assays based on diff erent methodology enabled us to investigate interdependence of D-dimer values and a correlation with total fi brinogen/fi brin degradation products (TDP). D-dimer concentrations were measured in plasma of 40 patients using NycoCard D-dimer, IL Test D-dimer, D-dimer PLUS, STA Liatest D-DI , and fi brinogen/fi brin degradation products were measured with Fibrinostika TDP. The samples were separeted into four groups according to NycoCard results: I.‹0.3 mg/L ; II.0.3-0.6 mg/L ; III. 0.7-1.2 mg/L ; IV.›1.2 mg/L.All assays gave comparable results in group IV. Majority of the results were comparable in group III, except for 4 samples that were negative:1 with STA Liatest D-DI and 3 with IL Test D-Dimer.The greatest discrepancy between results was found in group II (9/12 samples), above the NycoCard cut-off value. At 3/5 samples with normal NycoCard values (group I) we identifi ed 3 positive results :1 with STA Liatest D-DI and 2 with D-dimer PLUS assay.Results obtained by comparison of D-dimer concentration with NycoCard D-dimer and Vidas D-dimer indicated diff erences in 10/48 samples and comparison of IL test D-dimer and Vidas D-dimer gave discrepant results in 18/102 samples. The most discrepant results were at NycoCard value <=0.3 mg/L (7/10) and above cut-off value for IL Test D-dimer (16/102).In some samples we measured a signifi cantly higher values with NycoCard and IL Test Biochemia Medica 2006 ; 16(Suppl 1):S1–S268 S247 normalne ili tek neznatno povišene vrijednosti.U jednom od tih uzoraka dokazana je visoka koncentracija reumatoidnog faktora pa je i to jedan od čimbenika koji treba uzeti u obzir pri interpretaciji nalaza . Razlike dobivenih rezultata većinom su ipak posljedica uporabe različitih kalibratora i monoklonskih protutijela specifi čnih za pojedini test, što upućuje da je neophodno bolesnika pratiti uvijek istim testom.

Izvorni jezik
Hrvatski, engleski

Znanstvena područja
Temeljne medicinske znanosti



POVEZANOST RADA


Projekti:
0214212

Ustanove:
Klinika za plućne bolesti "Jordanovac",
Klinički bolnički centar Zagreb

Profili:

Avatar Url Renata Zadro (autor)

Avatar Url Vlasta Zovko (autor)


Citiraj ovu publikaciju:

Zovko, Vlasta; Coen Herak, Desiree; Živković, Marcela; Zadro, Renata
Dinamičko praćenje D-dimera različitim metodama za kvantitativno određivanje // Biochemia Medica
Poreč, Hrvatska, 2006. str. 246-247 (predavanje, domaća recenzija, sažetak, znanstveni)
Zovko, V., Coen Herak, D., Živković, M. & Zadro, R. (2006) Dinamičko praćenje D-dimera različitim metodama za kvantitativno određivanje. U: Biochemia Medica.
@article{article, author = {Zovko, Vlasta and Coen Herak, Desiree and \v{Z}ivkovi\'{c}, Marcela and Zadro, Renata}, year = {2006}, pages = {246-247}, keywords = {D-dimeri, razgradni produkti fibrinogena/fibrina}, title = {Dinami\v{c}ko pra\'{c}enje D-dimera razli\v{c}itim metodama za kvantitativno odre\djivanje}, keyword = {D-dimeri, razgradni produkti fibrinogena/fibrina}, publisherplace = {Pore\v{c}, Hrvatska} }
@article{article, author = {Zovko, Vlasta and Coen Herak, Desiree and \v{Z}ivkovi\'{c}, Marcela and Zadro, Renata}, year = {2006}, pages = {246-247}, keywords = {D-dimers, fibrinogen/fibrin degradation products}, title = {Dynamic D-dimer monitoring by different methods for quantitative determination}, keyword = {D-dimers, fibrinogen/fibrin degradation products}, publisherplace = {Pore\v{c}, Hrvatska} }

Časopis indeksira:


  • Scopus





Contrast
Increase Font
Decrease Font
Dyslexic Font