Pregled bibliografske jedinice broj: 258990
Particle emission measurement from cement furnace stack
Particle emission measurement from cement furnace stack // Proceedings of The 14th International Conference "AIR QUALITY - ASSESSMENT AND POLICY AT LOCAL, REGIONAL AND GLOBAL SCALES" / Krešimir, Šega (ur.).
Zagreb: Hrvatsko udruženje za zaštitu zraka (HUZZ), 2003. str. 173-181 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 258990 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Particle emission measurement from cement furnace stack
Autori
Pašalić, Goran ; Zdenko, Mikšik ; Zoran, Kovačević
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of The 14th International Conference "AIR QUALITY - ASSESSMENT AND POLICY AT LOCAL, REGIONAL AND GLOBAL SCALES"
/ Krešimir, Šega - Zagreb : Hrvatsko udruženje za zaštitu zraka (HUZZ), 2003, 173-181
Skup
The 14th International Conference "AIR QUALITY - ASSESSMENT AND POLICY AT LOCAL, REGIONAL AND GLOBAL SCALES"
Mjesto i datum
Dubrovnik, Hrvatska, 06.10.2003. - 10.10.2003
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
particle concentration measurement; electrostatic precipitator; cement furnace stack
Sažetak
In this paper practical problems of particle emission measurement from cement furnace stack and power plant stack have been presented. A description of problems encountered while providing measurements under different disturbances caused by technological process are given. Results of different measurements on the same cement furnace stack with two different types of stack gas particle filters (electrostatic precipitator and fine mechanical filter) have been presented and discussed.
Izvorni jezik
Engleski
POVEZANOST RADA
Projekti:
00220201
Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb