Pregled bibliografske jedinice broj: 258368
Kvaliteta slika radiograma toraksa komprimiranih algoritmima JPEG i JPEG2000
Kvaliteta slika radiograma toraksa komprimiranih algoritmima JPEG i JPEG2000 // Liječnički vjesnik / Čikeš, Nada (ur.).
Zagreb: Hrvatski liječnički zbor, 2006. (predavanje, međunarodna recenzija, sažetak, stručni)
CROSBI ID: 258368 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Kvaliteta slika radiograma toraksa komprimiranih algoritmima JPEG i JPEG2000
(Quality of chest X-ray images compressed using algorhytms JPEG and JPEG2000)
Autori
Milković, Đurđica ; Dodig, Matko ; Grgić, Sonja ; Dodig, Slavica ; Nogalo, Boro
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni
Izvornik
Liječnički vjesnik
/ Čikeš, Nada - Zagreb : Hrvatski liječnički zbor, 2006
Skup
IV. Congress of Croatian Society of Radiology with international participation
Mjesto i datum
Zagreb, Hrvatska, 11.10.2006. - 14.10.2006
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
radiogram; JPEG; JPEG2000; kompresija slika
(x-ray; JPEG; JPEG2000; image compression)
Sažetak
Background: For teleradiology routine X-ray images must be digitized with very high resolution and sent as purely digital files with no quality loss during transmission. The aim of this paper is to compare the quality of digitized chest X-ray images with digitally captured chest X-ray images in children, compressed using popular JPEG and JPEG2000 compression algorithms. Material: Eight upright posteroanterior chest X-ray images were selected for study: four images were photographed using digital camera, and four images were digitaly captured. Each X-ray image was compressed with six different compression degrees (3 bpp, 1.5 bpp, 1 bpp, 0.7 bpp, 0.5 bpp, 0.3 bpp, using JPEG and JPEG2000 algorhytms. Quality of compressed images was evaluated subjectively and by determination of objective measures: SNR, PSNR and MSE. Results: According to physician's subjective evaluation both JPEG and JPEG2000 compression for all X-ray digitized images (all radiologically relevant attributes) were accepted as excellent. PSNR and SNR values in digitaly captured images were lower than PSNR and SNR values in photographed/digitized images in both JPEG and JPEG2000 compression, respectively. There were no statistically significant difference between PSNR values in JPEG and JPEG2000 (p>0.05). Conclusion: To compression degree of 0.3 bpp both compression algorthms can be used for store-and-forward chest X-ray teleradiology.