Pregled bibliografske jedinice broj: 257089
Comparison of two methods for longissimus muscle area measurements
Comparison of two methods for longissimus muscle area measurements // Book of Abstracts of the 57th Annual Meeting of the European Association for Animal Production / Ynze van der Honing (ur.).
Wageningen: Wageningen Academic Publishers, 2006. (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 257089 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of two methods for longissimus muscle area measurements
Autori
Karolyi, Danijel ; Džidić, Alen ; Salajpal, Krešimir ; Đikić, Marija ; Jurić, Ivan
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Book of Abstracts of the 57th Annual Meeting of the European Association for Animal Production
/ Ynze van der Honing - Wageningen : Wageningen Academic Publishers, 2006
Skup
57th Annual Meeting of the European Association for Animal Production
Mjesto i datum
Antalya, Turska, 17.09.2006. - 20.09.2006
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
beef; m.longissimus dorsi; planimeter
Sažetak
The aim of the study was to determine the variance of longissimus muscle area (LMA) measurements associated with the standard use of polar planimeter (REISS Precision 3005, Germany) and ¨Image tool¨ software program. Measurements were conducted on six dorsal samples taken between 7th and 9th rib of the right halfs of beef carcasses. Firstly, LMA was traced on acetate paper and measured using a planimeter. Secondly, the images of longissimus muscles for computer analysis were obtained by scanning (UMAX PowerLook II) dorsal samples in ratio 1:1. LMA size was determined with ¨Image tool¨ software. Triplicate measurements of LMA were performed by six measurers for each sample and method. Variance components for LMA measurement method associated with measurer, sample and measurement replicates were estimated by REML. The proportion of the total variance in LMA measurement beetwen samples was greater with ¨Image tool¨ (99.79%) than with planimeter (96.49%). The proportion of variance between measurers was 0.12% with ¨Image tool¨ and 0.34% with planimeter. The proportion of error variance due to measurement replicates associated with the use of ¨Image tool¨ program was smaller (0.09 %) than with the planimeter (3.17%). The application of ¨Image tool¨ showed greater precision in measuring LMA than standard planimeter method.
Izvorni jezik
Engleski
Znanstvena područja
Poljoprivreda (agronomija)