Pregled bibliografske jedinice broj: 255759
The maintenance and repair of Dubrovnik bridge
The maintenance and repair of Dubrovnik bridge // Conference Report: Conference on Operation, Maintenance and Rehabilitation of Large Infrastructure Projects, Bridges and Tunnels / Vincentsen, Leif J. ; Larsen, Erik Stoklund (ur.).
Kopenhagen: International Association for Bridge and Structural Engineering (IABSE), 2006. str. 1-8 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 255759 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The maintenance and repair of Dubrovnik bridge
Autori
Šavor, Zlatko ; Hrelja, Gordana ; Radić, Jure
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Conference Report: Conference on Operation, Maintenance and Rehabilitation of Large Infrastructure Projects, Bridges and Tunnels
/ Vincentsen, Leif J. ; Larsen, Erik Stoklund - Kopenhagen : International Association for Bridge and Structural Engineering (IABSE), 2006, 1-8
Skup
Conference on Operation, Maintenance and Rehabilitation of Large Infrastructure Projects, Bridges and Tunnels
Mjesto i datum
Kopenhagen, Danska, 15.05.2006. - 17.05.2006
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
cable-stayed bridge; vibrations; repair; dampers
Sažetak
The Dubrovnik cable-stayed bridge is the only Croatian bridge of this type. This bridge has experienced vibrations of stay cables under certain wind conditions, as with many other cable-stayed bridges around the world. After a short review of results of wind tunnel tests and various numerical analyses, field observation of rain-wind induced stay cable vibrations are highlighted. Only after extremely violent movements of stay cables and the superstructure under heavy damp measures. Adjustable cable dampers, based on MR technology are to be installed on the bridge to raise low structural damping of mostly affected stay cables. Theoretical computations suggest that the stay cable vibrations shall be strongly reduced. Accelerometers and displacement transducers shall be placed on some stay cables to continuously monitor their motion.
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo