Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 250640

Analysis of the influence of operating conditions and geometric parameters on heat transfer in water-paraffin shell-and-tube latent thermal energy storage unit


Trp, Anica; Lenić, Kristian; Franković, Bernard
Analysis of the influence of operating conditions and geometric parameters on heat transfer in water-paraffin shell-and-tube latent thermal energy storage unit // Applied thermal engineering, 26 (2006), 16; 1830-1839 doi:10.1016/j.applthermaleng.2006.02.004 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 250640 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Analysis of the influence of operating conditions and geometric parameters on heat transfer in water-paraffin shell-and-tube latent thermal energy storage unit

Autori
Trp, Anica ; Lenić, Kristian ; Franković, Bernard

Izvornik
Applied thermal engineering (1359-4311) 26 (2006), 16; 1830-1839

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
latent thermal energy storage unit; simulation of transient heat transfer; influence of operating conditions and geometric parameters

Sažetak
A transient heat transfer phenomenon during charging and discharging of the shell-and-tube latent thermal energy storage system has been analysed in this paper. The mathematical model, regarding the conjugate problem of transient forced convection and solid-liquid phase change heat transfer based on the enthalpy formulation, has been presented. A fully implicit two-dimensional control volume FORTRAN computer code has been developed for solving governing equations with initial and boundary conditions. The numerical model is validated with experimental data obtained by experimental investigations that have been performed on the test unit with technical grade paraffin as the phase change material (PCM) and water as the heat transfer fluid (HTF). Numerical predictions match the experimental results. This pointed out that the presented numerical procedure could be accurately used for transient heat transfer simulation. A series of numerical calculations have been done in order to analyse the influence of several HTF operating conditions and several geometric parameters on the heat transfer process inside the water-paraffin shell-and-tube latent thermal energy storage (LTES) unit. Numerical results, which could be used for operating conditions and geometry optimization, provide guidelines for the design of the latent thermal energy storage system.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo, Temeljne tehničke znanosti



POVEZANOST RADA


Projekti:
0069001

Ustanove:
Tehnički fakultet, Rijeka

Profili:

Avatar Url Anica Trp (autor)

Avatar Url Kristian Lenić (autor)

Avatar Url Bernard Franković (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Trp, Anica; Lenić, Kristian; Franković, Bernard
Analysis of the influence of operating conditions and geometric parameters on heat transfer in water-paraffin shell-and-tube latent thermal energy storage unit // Applied thermal engineering, 26 (2006), 16; 1830-1839 doi:10.1016/j.applthermaleng.2006.02.004 (međunarodna recenzija, članak, znanstveni)
Trp, A., Lenić, K. & Franković, B. (2006) Analysis of the influence of operating conditions and geometric parameters on heat transfer in water-paraffin shell-and-tube latent thermal energy storage unit. Applied thermal engineering, 26 (16), 1830-1839 doi:10.1016/j.applthermaleng.2006.02.004.
@article{article, author = {Trp, Anica and Leni\'{c}, Kristian and Frankovi\'{c}, Bernard}, year = {2006}, pages = {1830-1839}, DOI = {10.1016/j.applthermaleng.2006.02.004}, keywords = {latent thermal energy storage unit, simulation of transient heat transfer, influence of operating conditions and geometric parameters}, journal = {Applied thermal engineering}, doi = {10.1016/j.applthermaleng.2006.02.004}, volume = {26}, number = {16}, issn = {1359-4311}, title = {Analysis of the influence of operating conditions and geometric parameters on heat transfer in water-paraffin shell-and-tube latent thermal energy storage unit}, keyword = {latent thermal energy storage unit, simulation of transient heat transfer, influence of operating conditions and geometric parameters} }
@article{article, author = {Trp, Anica and Leni\'{c}, Kristian and Frankovi\'{c}, Bernard}, year = {2006}, pages = {1830-1839}, DOI = {10.1016/j.applthermaleng.2006.02.004}, keywords = {latent thermal energy storage unit, simulation of transient heat transfer, influence of operating conditions and geometric parameters}, journal = {Applied thermal engineering}, doi = {10.1016/j.applthermaleng.2006.02.004}, volume = {26}, number = {16}, issn = {1359-4311}, title = {Analysis of the influence of operating conditions and geometric parameters on heat transfer in water-paraffin shell-and-tube latent thermal energy storage unit}, keyword = {latent thermal energy storage unit, simulation of transient heat transfer, influence of operating conditions and geometric parameters} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font