Quality of Chest X-ray Images Compressed Using JPEG and JPEG2000


Dodig, Matko; Grgić, Sonja; Dodig, Slavica
Quality of Chest X-ray Images Compressed Using JPEG and JPEG2000 // Proceedings of the EUROCON 2005 / David Simplot-Ryl (ur.).
Beograd: Institute of Electrical and Electronics Engineers (IEEE), 2005. str. 931-934 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 250583 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Quality of Chest X-ray Images Compressed Using JPEG and JPEG2000

Autori
Dodig, Matko ; Grgić, Sonja ; Dodig, Slavica

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the EUROCON 2005 / David Simplot-Ryl - Beograd : Institute of Electrical and Electronics Engineers (IEEE), 2005, 931-934

Skup
International Conference on "Computer as a Tool", EUROCON 2005

Mjesto i datum
Crna Gora; Beograd, Srbija, 21.11.2005. - 24.11.2005

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
chest radiograph; image analysis; image compression; teleradiology

Sažetak
The aim of this paper is to compare the quality of digitized chest X-ray images with digitally captured chest X-ray images in children with lung tuberculosis (TB), compressed using popular JPEG and JPEG2000 compression algorithms, for further electronic correspondence. All images were compressed using JPEG and JPEG2000 compression algorithms with six compression degrees (3 bpp, 1.5 bpp, 1 bpp, 0.7 bpp, 0.5 bpp, 0.3 bpp). Picture quality was evaluated by means of usual objective measures of picture quality such as MSE, SNR and PSNR. All compressed images were shown to physicians, who were asked to evaluate diagnostic accuracy of each image (by poor, good or excellent). According to physician's subjective evaluation both JPEG and JPEG2000 compression for all X-ray digitized images (all TB-attributes) were accepted as excellent.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0036015

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
Dječja bolnica Srebrnjak

Profili:

Avatar Url Slavica Dodig (autor)

Avatar Url Sonja Grgić (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Dodig, Matko; Grgić, Sonja; Dodig, Slavica
Quality of Chest X-ray Images Compressed Using JPEG and JPEG2000 // Proceedings of the EUROCON 2005 / David Simplot-Ryl (ur.).
Beograd: Institute of Electrical and Electronics Engineers (IEEE), 2005. str. 931-934 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Dodig, M., Grgić, S. & Dodig, S. (2005) Quality of Chest X-ray Images Compressed Using JPEG and JPEG2000. U: David Simplot-Ryl (ur.)Proceedings of the EUROCON 2005.
@article{article, author = {Dodig, Matko and Grgi\'{c}, Sonja and Dodig, Slavica}, year = {2005}, pages = {931-934}, keywords = {chest radiograph, image analysis, image compression, teleradiology}, title = {Quality of Chest X-ray Images Compressed Using JPEG and JPEG2000}, keyword = {chest radiograph, image analysis, image compression, teleradiology}, publisher = {Institute of Electrical and Electronics Engineers (IEEE)}, publisherplace = {Crna Gora; Beograd, Srbija} }
@article{article, author = {Dodig, Matko and Grgi\'{c}, Sonja and Dodig, Slavica}, year = {2005}, pages = {931-934}, keywords = {chest radiograph, image analysis, image compression, teleradiology}, title = {Quality of Chest X-ray Images Compressed Using JPEG and JPEG2000}, keyword = {chest radiograph, image analysis, image compression, teleradiology}, publisher = {Institute of Electrical and Electronics Engineers (IEEE)}, publisherplace = {Crna Gora; Beograd, Srbija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font