Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 249117

Measurement of Electric Field Probe Error for Pulsed Signals


Šarolić, Antonio; Roje, Vesna; Modlic, Borivoj
Measurement of Electric Field Probe Error for Pulsed Signals // 2006 IEEE International Symposium on Electromagnetic Compatibility
Portland (ME): Institute of Electrical and Electronics Engineers (IEEE), 2006. str. 244-248 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 249117 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Measurement of Electric Field Probe Error for Pulsed Signals

Autori
Šarolić, Antonio ; Roje, Vesna ; Modlic, Borivoj

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
2006 IEEE International Symposium on Electromagnetic Compatibility / - Portland (ME) : Institute of Electrical and Electronics Engineers (IEEE), 2006, 244-248

ISBN
1-4244-0293-X

Skup
2006 IEEE International Symposium on Electromagnetic Compatibility

Mjesto i datum
Portland (OR), Sjedinjene Američke Države, 14.08.2006. - 18.08.2006

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
electric field probe; measurement error; pulsed signals; calibration waveguide

Sažetak
Electric field probe performance is measured inside a calibration waveguide. The electric field probes based on diode detection are designed and calibrated for continuous signals. When measuring electric field strength of a pulsed waveform, performance degradation is expected. The degradation is measured in terms of measurement error. It is defined as electric field strength reading on the probe vs. actual electric field strength in the test volume of a calibration waveguide. Two such probes were measured. Test signals were pulsed (ASK) signals with fixed duty cycle of 1/10 and varying repetition frequency. The results show great differences among the two probes measured. One probe shows only slight degradation in terms of increased reading (positive measurement error) for high repetition frequencies. The second probe shows the same feature but of even greater extent, together with significant degradation for low repetition frequencies in terms of decreased reading (negative measurement error). The existence of such errors demands a great amount of caution during EMC measurements using diode-based electric field probes.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0036013
0023009

Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split,
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Borivoj Modlic (autor)

Avatar Url Vesna Roje (autor)

Avatar Url Antonio Šarolić (autor)


Citiraj ovu publikaciju:

Šarolić, Antonio; Roje, Vesna; Modlic, Borivoj
Measurement of Electric Field Probe Error for Pulsed Signals // 2006 IEEE International Symposium on Electromagnetic Compatibility
Portland (ME): Institute of Electrical and Electronics Engineers (IEEE), 2006. str. 244-248 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Šarolić, A., Roje, V. & Modlic, B. (2006) Measurement of Electric Field Probe Error for Pulsed Signals. U: 2006 IEEE International Symposium on Electromagnetic Compatibility.
@article{article, author = {\v{S}aroli\'{c}, Antonio and Roje, Vesna and Modlic, Borivoj}, year = {2006}, pages = {244-248}, keywords = {electric field probe, measurement error, pulsed signals, calibration waveguide}, isbn = {1-4244-0293-X}, title = {Measurement of Electric Field Probe Error for Pulsed Signals}, keyword = {electric field probe, measurement error, pulsed signals, calibration waveguide}, publisher = {Institute of Electrical and Electronics Engineers (IEEE)}, publisherplace = {Portland (OR), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }
@article{article, author = {\v{S}aroli\'{c}, Antonio and Roje, Vesna and Modlic, Borivoj}, year = {2006}, pages = {244-248}, keywords = {electric field probe, measurement error, pulsed signals, calibration waveguide}, isbn = {1-4244-0293-X}, title = {Measurement of Electric Field Probe Error for Pulsed Signals}, keyword = {electric field probe, measurement error, pulsed signals, calibration waveguide}, publisher = {Institute of Electrical and Electronics Engineers (IEEE)}, publisherplace = {Portland (OR), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }




Contrast
Increase Font
Decrease Font
Dyslexic Font