Pregled bibliografske jedinice broj: 248939
Monitoring of 60Co Radiation-Source Parameters by Optoelectronic Instrumentation
Monitoring of 60Co Radiation-Source Parameters by Optoelectronic Instrumentation // Proceedings of the Society of Photo-Optical Instrumentation Engineers, 2504 (1995), 486-491 (podatak o recenziji nije dostupan, kongresno priopcenje, znanstveni)
CROSBI ID: 248939 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Monitoring of 60Co Radiation-Source Parameters by Optoelectronic Instrumentation
Autori
Medved Rogina, Branka ; Skala, Karolj
Izvornik
Proceedings of the Society of Photo-Optical Instrumentation Engineers (0277-786X) 2504
(1995);
486-491
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, kongresno priopcenje, znanstveni
Ključne riječi
radiation source; monitoring; optoelectronic sensor
Sažetak
Problems of measurement the radiation dose level and determing the position of the 60Co radiation source rods are discussed. By radiation effects testing PCS fibre is found to have adequate sensitivity in the visible range up to 1.47x10-1 dB/kmGy, up to 10+3 60Co ionizing source radiation. The digital position sensor based on optoelectronic impulse source is developed, with accuracy +-1 mm for the whole vertical position change.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Institut "Ruđer Bošković", Zagreb
Citiraj ovu publikaciju:
Uključenost u ostale bibliografske baze podataka::