Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 245358

Kinematic Couplings for Synchrotron Radiation Instrumentation


Zelenika, Saša; Flechsig, Simone
Kinematic Couplings for Synchrotron Radiation Instrumentation // Proceedings of the 2nd International Workshop on Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation (MEDSI 2002)
Argonne (IL): ANL, 2003. str. 262-270 (predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 245358 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Kinematic Couplings for Synchrotron Radiation Instrumentation

Autori
Zelenika, Saša ; Flechsig, Simone

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 2nd International Workshop on Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation (MEDSI 2002) / - Argonne (IL) : ANL, 2003, 262-270

Skup
2nd International Workshop on Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation (MEDSI 2002)

Mjesto i datum
Lemont (IL), Sjedinjene Američke Države, 05.09.2002. - 06.09.2002

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Nije recenziran

Ključne riječi
kinematic mounts; Hertzian contacts; high-precision; X-ray equipment

Sažetak
Kinematic couplings are often used in synchrotron radiation facilities to achieve high-precision positioning and relocation of opto-mechanical components. The analytical and numerical modeling of their stress-strain behaviour is however difficult, as it implies the necessity to deal with the Hertz theory of point contacts between elastically deforming solids. This work adresses the limits of applicability of the analytical approaches available in literature for the calculation of high-precision kinematic couplings. The validity of the theoretical models, as well as the achievable repeatability of the couplings, is assessed experimentally for various loading conditions and material types.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Ustanove:
Tehnički fakultet, Rijeka

Profili:

Avatar Url Saša Zelenika (autor)


Citiraj ovu publikaciju:

Zelenika, Saša; Flechsig, Simone
Kinematic Couplings for Synchrotron Radiation Instrumentation // Proceedings of the 2nd International Workshop on Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation (MEDSI 2002)
Argonne (IL): ANL, 2003. str. 262-270 (predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)
Zelenika, S. & Flechsig, S. (2003) Kinematic Couplings for Synchrotron Radiation Instrumentation. U: Proceedings of the 2nd International Workshop on Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation (MEDSI 2002).
@article{article, author = {Zelenika, Sa\v{s}a and Flechsig, Simone}, year = {2003}, pages = {262-270}, keywords = {kinematic mounts, Hertzian contacts, high-precision, X-ray equipment}, title = {Kinematic Couplings for Synchrotron Radiation Instrumentation}, keyword = {kinematic mounts, Hertzian contacts, high-precision, X-ray equipment}, publisher = {ANL}, publisherplace = {Lemont (IL), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }
@article{article, author = {Zelenika, Sa\v{s}a and Flechsig, Simone}, year = {2003}, pages = {262-270}, keywords = {kinematic mounts, Hertzian contacts, high-precision, X-ray equipment}, title = {Kinematic Couplings for Synchrotron Radiation Instrumentation}, keyword = {kinematic mounts, Hertzian contacts, high-precision, X-ray equipment}, publisher = {ANL}, publisherplace = {Lemont (IL), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }




Contrast
Increase Font
Decrease Font
Dyslexic Font