Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 245205

Sensitive turn-to-turn fault protection for power transformers


Gajić, Zoran; Brnčić, Ivo; Hillström, Birger; Ivanković, Igor
Sensitive turn-to-turn fault protection for power transformers // Cigré Study Committee B5 Colloquium and IEEE Power System Relaying Committee / de Mesmaeker, Ivan ; Hindle, Paul (ur.).
Calgary: CIGRÉ, 2005. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 245205 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Sensitive turn-to-turn fault protection for power transformers

Autori
Gajić, Zoran ; Brnčić, Ivo ; Hillström, Birger ; Ivanković, Igor

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Cigré Study Committee B5 Colloquium and IEEE Power System Relaying Committee / De Mesmaeker, Ivan ; Hindle, Paul - Calgary : CIGRÉ, 2005

Skup
Joint Meetings of Cigré Study Committee B5 and IEEE Power System Relaying Committee, with the Study Committee B5 Colloquium

Mjesto i datum
Calgary, Kanada, 08.09.2005. - 16.09.2005

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
power transformer; sensitive differential protection; turn-to-turn fault

Sažetak
Three most typical weaknesses of the analogue power transformer differential relays have been: 1. Long operating time in case of heavy internal faults followed by main CT saturation 2. Unwanted operations for external faults and transformer inrush 3. Bad sensitivity for low-level internal faults, such as winding turn-to-turn faults With the introduction of the numerical technology the first two problems could be handled in much better way [4]. However sensitivity for internal winding turn-to-turn faults did not improve much. This paper introduces the new protection principle, which will improve differential relay sensitivity for minor internal turn-to-turn faults. However, the first two classical disadvantages are as well efficiently removed by applying the solution described in the paper.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Igor Ivanković (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Gajić, Zoran; Brnčić, Ivo; Hillström, Birger; Ivanković, Igor
Sensitive turn-to-turn fault protection for power transformers // Cigré Study Committee B5 Colloquium and IEEE Power System Relaying Committee / de Mesmaeker, Ivan ; Hindle, Paul (ur.).
Calgary: CIGRÉ, 2005. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Gajić, Z., Brnčić, I., Hillström, B. & Ivanković, I. (2005) Sensitive turn-to-turn fault protection for power transformers. U: de Mesmaeker, I. & Hindle, P. (ur.)Cigré Study Committee B5 Colloquium and IEEE Power System Relaying Committee.
@article{article, author = {Gaji\'{c}, Zoran and Brn\v{c}i\'{c}, Ivo and Hillstr\"{o}m, Birger and Ivankovi\'{c}, Igor}, year = {2005}, pages = {broj referata 113}, keywords = {power transformer, sensitive differential protection, turn-to-turn fault}, title = {Sensitive turn-to-turn fault protection for power transformers}, keyword = {power transformer, sensitive differential protection, turn-to-turn fault}, publisher = {CIGR\'{E}}, publisherplace = {Calgary, Kanada} }
@article{article, author = {Gaji\'{c}, Zoran and Brn\v{c}i\'{c}, Ivo and Hillstr\"{o}m, Birger and Ivankovi\'{c}, Igor}, year = {2005}, pages = {broj referata 113}, keywords = {power transformer, sensitive differential protection, turn-to-turn fault}, title = {Sensitive turn-to-turn fault protection for power transformers}, keyword = {power transformer, sensitive differential protection, turn-to-turn fault}, publisher = {CIGR\'{E}}, publisherplace = {Calgary, Kanada} }