Pregled bibliografske jedinice broj: 2447
Detection of surface activity by voltammetric measurements
Detection of surface activity by voltammetric measurements // Electroanalysis, 7 (1995), 7; 652-655 doi:10.1002/elan.1140070710 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 2447 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Detection of surface activity by voltammetric measurements
Autori
Komorsky-Lovrić, Šebojka ; Lovrić, Milivoj ; Branica, Marko
Izvornik
Electroanalysis (1040-0397) 7
(1995), 7;
652-655
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
surface activity ; surfactant ; adsorption ; triton-X-100 ; cadmium
Sažetak
Influences of a nonionic detergent Triton X-100 on square-wave voltammetry and anodic stripping square-wave voltammetry of Cd2+ in 0.5 M NaClO4 + 0.01 M HClO4 are measured at precisely controlled durations of adsorptive accumulation and surfactant concentrations. Diagnostic criteria for the presence of surface-active substances in electrolytes are reported. A voltammetric method for the quantitative analysis of detergents is proposed. An ionic type of detergent can be recognized by the variation of the accumulation potential.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Scopus