Pregled bibliografske jedinice broj: 237120
Direct Parallel Connection of DC-DC Power Circuits with Galvanic Isolation
Direct Parallel Connection of DC-DC Power Circuits with Galvanic Isolation // EDPE 2005. Conference CD / Jakopović, Željko (ur.).
Zagreb: Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA), 2005. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 237120 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Direct Parallel Connection of DC-DC Power Circuits with Galvanic Isolation
Autori
Čobanov, Neven
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
EDPE 2005. Conference CD
/ Jakopović, Željko - Zagreb : Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA), 2005
Skup
13^th International Conference on Electrical Drives and Power Electronics. 2^nd Joint Croatia-Slovakia Conference
Mjesto i datum
Dubrovnik, Hrvatska, 26.09.2005. - 28.09.2005
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
DC power supplies; converter control; parallel converter connection
Sažetak
A DC-DC converter made of two identical IGBT full bridge power circuits is built. The two circuits are directly connected in parallel and driven with only one control circuit originally built for one IGBT bridge. One signal drives two corresponding IGBTs in parallel bridges without any additional circuits for current sharing. The main causes of possible current unbalance were identified by simulation. The difference among transformer leakage inductances has, by far, the most significant influence on current sharing between two circuits. This was confirmed by measurements. It is concluded that transformer tolerances regarding leakage inductances that can be achieved in normal series production will ensure an acceptable current sharing.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika