Pregled bibliografske jedinice broj: 226701
Comparison of conventional Spin-Echo and Fast Spin-Echo magnetic resonance imaging with fat suppression in crutiate ligament injury
Comparison of conventional Spin-Echo and Fast Spin-Echo magnetic resonance imaging with fat suppression in crutiate ligament injury // Croatian Medical Journal, 45 (2004), 2; 195-201 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 226701 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of conventional Spin-Echo and Fast Spin-Echo magnetic resonance imaging with fat suppression in crutiate ligament injury
Autori
Borić, Igor ; Pećina, Marko ; Bojanić, Ivan ; Hašpl, Miroslav ; Roić, Goran
Izvornik
Croatian Medical Journal (0353-9504) 45
(2004), 2;
195-201
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
knee MR; ACL rupture
Sažetak
AIM: To compare the quality and diagnostic reliability of conventional spin-echo and fast spin-echo with fat suppression magnetic resonance (MR) imaging in the evaluation of cruciate ligament injury. METHODS: Thirty-five patients with internal knee injury and positive clinical signs of cruciate ligament injury were examined by using an Elscint Prestige 2T MR scanner. Findings of conventional and fast spin-echo with fat suppression MR sequences were evaluated and compared with each other and with arthroscopic findings. In all patients, arthroscopy was performed within 2 months after the MR examination. RESULTS: Analysis of anterior cruciate ligament injury with conventional spin-echo sequence showed 81.8% sensitivity. The sensitivity of fast spin-echo sequences with fat suppression was 96.9%. According to the type of the anterior cruciate ligament injury, the sensitivity of fast spin-echo sequences with fat suppression was higher than that of conventional spin-echo sequence (85.7% and 66.7%, respectively) for partial rupture, but the sensitivity of both sequences for complete rupture was the same (100% both). CONCLUSION: Fast spin-echo with fat suppression sequence can be used routinely in clinical practice for the assessment of acutely injured knees as the substitute for conventional spin-echo sequence without decreased diagnostic reliability.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb
Profili:
Goran Roić
(autor)
Miroslav Hašpl
(autor)
Igor Borić
(autor)
Marko Pećina
(autor)
Ivan Bojanić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE