Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 221904

CHOPPING FREQUENCY OPTIMIZING IN THE NIR MOISTURE METER


Filić, Mirko; Ćorluka, Venco; Valter, Zdravko
CHOPPING FREQUENCY OPTIMIZING IN THE NIR MOISTURE METER // ATDC`05 Proceedings of the 4th DAAAM International Conference on Advanced Technologies for Developing Countries / Kljajin, Milan ; Katalinić, Branko ; Budić, Ivan (ur.).
Slavonski Brod: Josip Juraj Strossmayer University of Osijek, Croatia ; Mechanical Engineering Faculty in Slavonski Brod ; DAAM International, Vienna, 2005. str. 503-508 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 221904 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
CHOPPING FREQUENCY OPTIMIZING IN THE NIR MOISTURE METER

Autori
Filić, Mirko ; Ćorluka, Venco ; Valter, Zdravko

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
ATDC`05 Proceedings of the 4th DAAAM International Conference on Advanced Technologies for Developing Countries / Kljajin, Milan ; Katalinić, Branko ; Budić, Ivan - Slavonski Brod : Josip Juraj Strossmayer University of Osijek, Croatia ; Mechanical Engineering Faculty in Slavonski Brod ; DAAM International, Vienna, 2005, 503-508

Skup
4th DAAAM International Conference on Andvanced Technologies for Developing Countries

Mjesto i datum
Slavonski Brod, Hrvatska, 21.09.2005. - 24.09.2005

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
moisture meter; NIR; near infrared; chopping frequency

Sažetak
The near infrared (NIR) moisture meter is designed and realised by the authors. Its optoelectronic part is theoretically and practically analysed in this paper by means of the measuring results. The measurement system is based on the cooled PbS photoconductive detector and a mechanical chopper. The moisture measuring is realized via reflected radiation at narrow band range around 1940nm in the NIR region. The signal obtained from the detector can be very small and mixes with the noises from various sources. The optimal chopping frequency is estimated regarding the resumption of the maximal output detector signal and maximal signal versus noise ratio with other given parameters. The power line generated noise as well as its influence on the optoelectronic system and on the measuring results are partly removed with the embedded frequency filter and partly with the choice of the matching chopping frequency.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0165109

Ustanove:
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek

Profili:

Avatar Url Mirko Filić (autor)

Avatar Url Venco Ćorluka (autor)

Avatar Url Zdravko Valter (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Filić, Mirko; Ćorluka, Venco; Valter, Zdravko
CHOPPING FREQUENCY OPTIMIZING IN THE NIR MOISTURE METER // ATDC`05 Proceedings of the 4th DAAAM International Conference on Advanced Technologies for Developing Countries / Kljajin, Milan ; Katalinić, Branko ; Budić, Ivan (ur.).
Slavonski Brod: Josip Juraj Strossmayer University of Osijek, Croatia ; Mechanical Engineering Faculty in Slavonski Brod ; DAAM International, Vienna, 2005. str. 503-508 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Filić, M., Ćorluka, V. & Valter, Z. (2005) CHOPPING FREQUENCY OPTIMIZING IN THE NIR MOISTURE METER. U: Kljajin, M., Katalinić, B. & Budić, I. (ur.)ATDC`05 Proceedings of the 4th DAAAM International Conference on Advanced Technologies for Developing Countries.
@article{article, author = {Fili\'{c}, Mirko and \'{C}orluka, Venco and Valter, Zdravko}, year = {2005}, pages = {503-508}, keywords = {moisture meter, NIR, near infrared, chopping frequency}, title = {CHOPPING FREQUENCY OPTIMIZING IN THE NIR MOISTURE METER}, keyword = {moisture meter, NIR, near infrared, chopping frequency}, publisher = {Josip Juraj Strossmayer University of Osijek, Croatia ; Mechanical Engineering Faculty in Slavonski Brod ; DAAM International, Vienna}, publisherplace = {Slavonski Brod, Hrvatska} }
@article{article, author = {Fili\'{c}, Mirko and \'{C}orluka, Venco and Valter, Zdravko}, year = {2005}, pages = {503-508}, keywords = {moisture meter, NIR, near infrared, chopping frequency}, title = {CHOPPING FREQUENCY OPTIMIZING IN THE NIR MOISTURE METER}, keyword = {moisture meter, NIR, near infrared, chopping frequency}, publisher = {Josip Juraj Strossmayer University of Osijek, Croatia ; Mechanical Engineering Faculty in Slavonski Brod ; DAAM International, Vienna}, publisherplace = {Slavonski Brod, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font