Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 2084

Determination of dose distribution in the veterinarian X ray diagnostics


Ranogajec-Komor, Maria; Šimpraga, Miljenko; Butković, V.
Determination of dose distribution in the veterinarian X ray diagnostics // Abstracts of paper of the 21st Workshop on radiation protection / Pellet, Sandor (ur.).
Budimpešta: Roland Eotvos Physical Society, Health Physics Section, 1996. str. 76-76 (predavanje, nije recenziran, sažetak, stručni)


CROSBI ID: 2084 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Determination of dose distribution in the veterinarian X ray diagnostics

Autori
Ranogajec-Komor, Maria ; Šimpraga, Miljenko ; Butković, V.

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
Abstracts of paper of the 21st Workshop on radiation protection / Pellet, Sandor - Budimpešta : Roland Eotvos Physical Society, Health Physics Section, 1996, 76-76

Skup
21st Workshop on Radiation Protection

Mjesto i datum
Balatonkenese, Mađarska, 22.05.1996. - 24.05.1996

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Nije recenziran

Ključne riječi
-

Sažetak
The basis of radiation protection is the exact knowledge of absorbed dose. The dose determination in X-ray diagnostics is not a simple task because variable low-energy radiation has to be measured. Therefore the vetrinarian X-ray equipment and the used dosimetric sysem were first tested and their reliability determined. It was found that the dosimetric system used i.e. the TLD-700 detectors combined with a computerized TOLEDO 654 reader meet the requirements of dose determination in the X-ray diagnostics. After determination of the uncertainty of the dosimetry system, of the irradiation field homogeneity and of the reproducibility of the X-ray irradiation procedure, the organ doses received in X-ray wxamination of abdomen and pelvis of dogs were measured. The standard deviation of dose in the primary beam in 4 measurement cycles was +-5%, while the standard deviation of dose to organs was +- 25-30%. The analysis of the dosiemtric results in the vetrinarian X-ray diagnostics shows that besides the radiation damage the dose distribution (organ doses) can be estimated on the basis of the primary beam dose measurements.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
00980904

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Ferencne Ranogajec (autor)

Avatar Url Miljenko Šimpraga (autor)


Citiraj ovu publikaciju:

Ranogajec-Komor, Maria; Šimpraga, Miljenko; Butković, V.
Determination of dose distribution in the veterinarian X ray diagnostics // Abstracts of paper of the 21st Workshop on radiation protection / Pellet, Sandor (ur.).
Budimpešta: Roland Eotvos Physical Society, Health Physics Section, 1996. str. 76-76 (predavanje, nije recenziran, sažetak, stručni)
Ranogajec-Komor, M., Šimpraga, M. & Butković, V. (1996) Determination of dose distribution in the veterinarian X ray diagnostics. U: Pellet, S. (ur.)Abstracts of paper of the 21st Workshop on radiation protection.
@article{article, author = {Ranogajec-Komor, Maria and \v{S}impraga, Miljenko and Butkovi\'{c}, V.}, editor = {Pellet, S.}, year = {1996}, pages = {76-76}, keywords = {-}, title = {Determination of dose distribution in the veterinarian X ray diagnostics}, keyword = {-}, publisher = {Roland Eotvos Physical Society, Health Physics Section}, publisherplace = {Balatonkenese, Ma\djarska} }
@article{article, author = {Ranogajec-Komor, Maria and \v{S}impraga, Miljenko and Butkovi\'{c}, V.}, editor = {Pellet, S.}, year = {1996}, pages = {76-76}, keywords = {-}, title = {Determination of dose distribution in the veterinarian X ray diagnostics}, keyword = {-}, publisher = {Roland Eotvos Physical Society, Health Physics Section}, publisherplace = {Balatonkenese, Ma\djarska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font