Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 2067

Determination of patient surface doses from computerized tomography examination of the head


Vekić, Branko; Ranogajec-Komor, Maria
Determination of patient surface doses from computerized tomography examination of the head // Radiation Protection Dosimetry, 66 (1996), 1-4, part 2; 311-314 doi:10.1093/oxfordjournals.rpd.a031741 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 2067 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Determination of patient surface doses from computerized tomography examination of the head

Autori
Vekić, Branko ; Ranogajec-Komor, Maria

Izvornik
Radiation Protection Dosimetry (0144-8420) 66 (1996), 1-4, part 2; 311-314

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
DOSIMETRY

Sažetak
The radiation doses absorbed by various organs of patients (gonads, chest, thyroid and the lens of the eye) were measured at the body surface of patients during computerised tomography (CT), examinations of the head. According to our earlier energy response studies with X ray irradiations, the TL responses of LiF TLDs have the lowest energy dependence and hence LiF:Mg, Ti TLD discs (produced in Poland) and TLD-700 (Harshaw) were used for measurements of the dose. Approximately 600 TLD discs and 200 TLD-700 were used in this study for surface organ dose measurements on 54 patients of different sex and age. The highest dose measured in this study (71.10 mGy) was delivered to the eye lens during a CT examination of the head.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
00980904

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Branko Vekić (autor)

Avatar Url Ferencne Ranogajec (autor)

Poveznice na cjeloviti tekst rada:

doi academic.oup.com

Citiraj ovu publikaciju:

Vekić, Branko; Ranogajec-Komor, Maria
Determination of patient surface doses from computerized tomography examination of the head // Radiation Protection Dosimetry, 66 (1996), 1-4, part 2; 311-314 doi:10.1093/oxfordjournals.rpd.a031741 (međunarodna recenzija, članak, znanstveni)
Vekić, B. & Ranogajec-Komor, M. (1996) Determination of patient surface doses from computerized tomography examination of the head. Radiation Protection Dosimetry, 66 (1-4, part 2), 311-314 doi:10.1093/oxfordjournals.rpd.a031741.
@article{article, author = {Veki\'{c}, Branko and Ranogajec-Komor, Maria}, year = {1996}, pages = {311-314}, DOI = {10.1093/oxfordjournals.rpd.a031741}, keywords = {DOSIMETRY}, journal = {Radiation Protection Dosimetry}, doi = {10.1093/oxfordjournals.rpd.a031741}, volume = {66}, number = {1-4, part 2}, issn = {0144-8420}, title = {Determination of patient surface doses from computerized tomography examination of the head}, keyword = {DOSIMETRY} }
@article{article, author = {Veki\'{c}, Branko and Ranogajec-Komor, Maria}, year = {1996}, pages = {311-314}, DOI = {10.1093/oxfordjournals.rpd.a031741}, keywords = {DOSIMETRY}, journal = {Radiation Protection Dosimetry}, doi = {10.1093/oxfordjournals.rpd.a031741}, volume = {66}, number = {1-4, part 2}, issn = {0144-8420}, title = {Determination of patient surface doses from computerized tomography examination of the head}, keyword = {DOSIMETRY} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font