Pregled bibliografske jedinice broj: 19656
Reracking Possibilities of the NPP Krško Spent Fuel Pool
Reracking Possibilities of the NPP Krško Spent Fuel Pool // International Conference: Nuclear Option in Countries with Small and Medium Electricity Grids, Conference Proceedings / Knapp, Vladimir ; Čavlina, Nikola (ur.).
Zagreb: Hrvatsko nuklearno društvo, 1998. str. 365-371 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 19656 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Reracking Possibilities of the NPP Krško Spent Fuel Pool
Autori
Baće, Mile ; Pevec, Dubravko ; Šmuc, Tomislav
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
International Conference: Nuclear Option in Countries with Small and Medium Electricity Grids, Conference Proceedings
/ Knapp, Vladimir ; Čavlina, Nikola - Zagreb : Hrvatsko nuklearno društvo, 1998, 365-371
Skup
Nuclear Option in Countries with Small and Medium Electricity Grids
Mjesto i datum
Dubrovnik, Hrvatska, 15.06.1998. - 18.06.1998
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
reracking; spent fuel pool; multiplication factor
Sažetak
Using the SCALE-4 code package reracking possibilities of the NPP Krško spent fuel pool were analyzed. Two cases were considered: the first case assuming the 40 years lifetime of the plant, and the second case assuming the 50 years lifetime of the plant. It was shown that it is possible to design the additional racks in free space of the spent fuel pool with the sufficient total capacity to store all the spent fuel generated during the 40 years lifetime of the plant. In the case of 50 years plant lifetime, completely new racks (capacity of 1890 spent fuel assemblies), containing 4mm boral in storage cell walls, were proposed for the NPP Krško spent fuel pool. The effective multiplication factor of the spent fuel pool fully loaded with new racks containing spent fuel assemblies of initial enrichment 4.3 w/o, burned to 40 GWd/tU and cooled 2 years is lower than the value required by standard. It showed the possibility of the safe disposal of all spent fuel accumulated during more than 50 years lifetime of the plant.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika