Pregled bibliografske jedinice broj: 19641
Incorporation of multi-layer option into QAD-CGGP code
Incorporation of multi-layer option into QAD-CGGP code // Nuclear Energy in Central Europe '98, Proceedings / Ravnik, Matjaž ; Jenčič, Igor ; Žagar, Tomaž (ur.).
Ljubljana: Nuclear Society of Slovenia, 1998. str. 139-146 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 19641 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Incorporation of multi-layer option into QAD-CGGP code
Autori
Trontl, Krešimir ; Baće, Mile ; Šmuc, Tomislav
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Nuclear Energy in Central Europe '98, Proceedings
/ Ravnik, Matjaž ; Jenčič, Igor ; Žagar, Tomaž - Ljubljana : Nuclear Society of Slovenia, 1998, 139-146
Skup
Nuclear Energy in Central Europe
Mjesto i datum
Čatež ob Savi, Slovenija, 07.09.1998. - 10.09.1998
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
multi-layer shield; dose rates; buildup factor
Sažetak
In order to improve the results of the QAD-CGGP gamma dose rate calculation we have incorporated multi-layer (two-layer) shield option and a new buildup factor formula, published recently, into the code. Modified QAD has been tested by comparison to the published results. The improved version of the code has been used to calculate gamma dose rate of a planar source and a two-layer shield and the results have been compared with the SAS4 (Monte Carlo method). Also, the improved version of the code has been used to calculate dose rate of the RADLOK-55 low and intermediate waste drum placed inside the NPP Krško transport (lead-iron) shield. The results of the calculation were compared with the standard QAD-CGGP results. Incorporation of the two-layer (multi-layer) option into QAD-CGGP point-kernel code seems to be justified, resulting in higher accuracy.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika