Pregled bibliografske jedinice broj: 170412
Influence of the Joule-Thompson Effesct on Geothermal Energy Production at the Reservoir Velika Ciglena
Influence of the Joule-Thompson Effesct on Geothermal Energy Production at the Reservoir Velika Ciglena // Međunarodni kongres Energija i okoliš 2004. : 19. znanstveni skup o energiji i zaštiti okoliša : zbornik = International Congress Energy and the Environment : 19th Scientific Conference on Energy and the Environment : proceedings ; Vol. 2 / Franković, Bernard (ur.).
Rijeka: Hrvatski savez za sunčevu energiju, 2004. str. 33-38 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 170412 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Influence of the Joule-Thompson Effesct on Geothermal Energy Production at the Reservoir Velika Ciglena
Autori
Golub, Miroslav ; Kurevija, Tomislav ; Koščak Kolin, Sonja
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Međunarodni kongres Energija i okoliš 2004. : 19. znanstveni skup o energiji i zaštiti okoliša : zbornik = International Congress Energy and the Environment : 19th Scientific Conference on Energy and the Environment : proceedings ; Vol. 2
/ Franković, Bernard - Rijeka : Hrvatski savez za sunčevu energiju, 2004, 33-38
ISBN
953-6886-08-1
Skup
Međunarodni kongres Energija i okoliš (19 ; 2004)
Mjesto i datum
Opatija, Hrvatska, 27.10.2004. - 29.10.2004
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
temperature profile; geothermal production optimization
Sažetak
Geothermal reservoir Velika Ciglena is placed 11 km south-east from the city Bjelovar. It is the high-temperature reservoir, according to the physical characteristics of rocks. So far, four wells have been made. Optimal production of the geothermal energy can be obtained on the well VC-1A, due to the production equipment and thermodynamic conditions of the reservoir. The well is 2881 m deep, with the static pressure of 247, 3 bar and the static temperature of 175°C. Production layer is located on the 2 543 m. The geothermal water production should flow through the annular space between the tubing and the casing, which are designed for the wellhead pressure of 20 bar. Calculations shows that the temperature of the geothermal water on the wellhead should be about 170°C, if the flow is 10 000 m3/h, based on the Duns-Ros methodology. In determination of the optimal temperature, the Joule-Thompson effect should be applied, as it strongly influences all gases and liquids, being important for geothermal water as well.
Izvorni jezik
Engleski
Znanstvena područja
Rudarstvo, nafta i geološko inženjerstvo