Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 169251

Impact of vertebrobasilar junction geometry on hemodynamics in basilar artery 3D ultrasound study


Zavoreo, Iris; Kesić, Miljenka; Lovrenčić Huzjan, Ariana; Vuković, Vlasta; Demarin, Vida
Impact of vertebrobasilar junction geometry on hemodynamics in basilar artery 3D ultrasound study // Cerebrovascular Diseases, 17 (suppl 4) (2004) (podatak o recenziji nije dostupan, kongresno priopcenje, znanstveni)


CROSBI ID: 169251 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Impact of vertebrobasilar junction geometry on hemodynamics in basilar artery 3D ultrasound study

Autori
Zavoreo, Iris ; Kesić, Miljenka ; Lovrenčić Huzjan, Ariana ; Vuković, Vlasta ; Demarin, Vida

Izvornik
Cerebrovascular Diseases (1015-9770) 17 (suppl 4) (2004);

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, kongresno priopcenje, znanstveni

Ključne riječi
vertebrobasilar; 3D ultrasound; geometry

Sažetak
Introduction: In our previous studies we showed that three-dimensional ultrasound (3D US) reconstuction of images from Transcranial color-coded sonography (TCCS) and power Doppler imaging is very usefull in evaluation of the vertebrobasilar (VB) system. In most indviduals the origin of the basilar artery (BA) can not be visualised due to unfavourable angle of the vertebral arteries (VA) junction or unfavourable angle of insonation. In such cases 3D US enables mathematically reconstruction of the VB junction. The aim of this study was to calculate the angle of VB junction by means of 3D US and applie it into the vector analisys of the VB junction hemodinamics. Patients and methods: We tried to display the 3D images of the intracranial parts of the VA and BA. Interactive 3D imaging software was integrated into an ultrasound platform (Aloka Prosound 5500). Data aquisition was performed using 2, 5 MHz sector transducer, freehanded in a fixed length of time (10 seconds), allowing Power Doppler (PD) sonography. The images were postprocessed (TomTec imaging system). The technique was applied in 25 patients in order to visualise all three vessels at the time, and to calculate the angle between each pair of vessels, according to the direction of the blood vessels. Hemodynamic parameters such as mean blood velocity(MBFV), pulsatility index(PI) and resistance index(RI) were measured in all three vessels. Vector analysis was applied for each hemodynamic parameter. We took real time measured MBFV, PI and RI values for VA and the angle value between VA and BA. We tried to find correlation between real time measured MBFV, PI and RI in BA and mathematically calculated values for BA. Results: In TCCS the angle between VA could be obtained in 19/25 patients. In 6 patients the angle between VA and BA origin couldn’ t be adequately visualised, but mathematical reconstruction according to the direction of the blood vessels was possible. Conclusion: 3D US enabled calculation of the angle between VA and BA.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
0134015

Ustanove:
KBC "Sestre Milosrdnice"


Citiraj ovu publikaciju:

Zavoreo, Iris; Kesić, Miljenka; Lovrenčić Huzjan, Ariana; Vuković, Vlasta; Demarin, Vida
Impact of vertebrobasilar junction geometry on hemodynamics in basilar artery 3D ultrasound study // Cerebrovascular Diseases, 17 (suppl 4) (2004) (podatak o recenziji nije dostupan, kongresno priopcenje, znanstveni)
Zavoreo, I., Kesić, M., Lovrenčić Huzjan, A., Vuković, V. & Demarin, V. (2004) Impact of vertebrobasilar junction geometry on hemodynamics in basilar artery 3D ultrasound study. Cerebrovascular Diseases, 17 (suppl 4).
@article{article, author = {Zavoreo, Iris and Kesi\'{c}, Miljenka and Lovren\v{c}i\'{c} Huzjan, Ariana and Vukovi\'{c}, Vlasta and Demarin, Vida}, year = {2004}, pages = {26}, keywords = {vertebrobasilar, 3D ultrasound, geometry}, journal = {Cerebrovascular Diseases}, volume = {17 (suppl 4)}, issn = {1015-9770}, title = {Impact of vertebrobasilar junction geometry on hemodynamics in basilar artery 3D ultrasound study}, keyword = {vertebrobasilar, 3D ultrasound, geometry} }
@article{article, author = {Zavoreo, Iris and Kesi\'{c}, Miljenka and Lovren\v{c}i\'{c} Huzjan, Ariana and Vukovi\'{c}, Vlasta and Demarin, Vida}, year = {2004}, pages = {26}, keywords = {vertebrobasilar, 3D ultrasound, geometry}, journal = {Cerebrovascular Diseases}, volume = {17 (suppl 4)}, issn = {1015-9770}, title = {Impact of vertebrobasilar junction geometry on hemodynamics in basilar artery 3D ultrasound study}, keyword = {vertebrobasilar, 3D ultrasound, geometry} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font