Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 167590

Palladium hexacyanoferrate hydrogel as novel and simple enzyme immobilization matrix for amperometric biosensors


Iveković, Damir; Milardović, Stjepan; Grabarić, S. Božidar
Palladium hexacyanoferrate hydrogel as novel and simple enzyme immobilization matrix for amperometric biosensors // Biosensors & bioelectronics, 20 (2004), 872-878 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 167590 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Palladium hexacyanoferrate hydrogel as novel and simple enzyme immobilization matrix for amperometric biosensors

Autori
Iveković, Damir ; Milardović, Stjepan ; Grabarić, S. Božidar

Izvornik
Biosensors & bioelectronics (0956-5663) 20 (2004); 872-878

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Glucose biosensor; Glucose oxidase; Hydrogel; Nickel hexacyanoferrate; Amperometric

Sažetak
Abstract: An amperometric glucose biosensor with glucose oxidase immobilized into palladium hexacyanoferrate hydrogel has been prepared and evaluated. The sensor was based on a two-layer configuration, with biocatalytic and electrocatalytic layers separately deposited onto the electrode. To reduce the overpotential for reduction of hydrogen peroxide liberated in the enzyme catalyzed oxidation of glucose, an inner thin layer of nickel hexacyanoferrate electrodeposited onto the surface of graphite electrode was used as an electrocatalyst. As an outer layer the hydrogel of palladium hexacyanoferrate with entrapped glucose oxidase was used. Under optimal operating conditions (pH = 5.0 and E = - 0.075 V vs. calomel (3.0 M KCl) reference electrode) sensor showed high sensitivity to glucose (0.3 - 1.0 mA/mM) and a response time of less than 30 s. The linear response to glucose was obtained in the concentration range between 0.05 and 1.0 mM in batch analysis mode, and 0 - 7.0 mM in FIA. During the 32-days testing period no significant decrease in the sensor sensitivity was observed. The sensor was applied for the determination of glucose concentration in fruit juice and yoghurt drink, and the results obtained showed good correlation with results obtained by reference spectrophotometric enzyme method.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
0125054
0058016

Ustanove:
Prehrambeno-biotehnološki fakultet, Zagreb,
Fakultet kemijskog inženjerstva i tehnologije, Zagreb

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Iveković, Damir; Milardović, Stjepan; Grabarić, S. Božidar
Palladium hexacyanoferrate hydrogel as novel and simple enzyme immobilization matrix for amperometric biosensors // Biosensors & bioelectronics, 20 (2004), 872-878 (međunarodna recenzija, članak, znanstveni)
Iveković, D., Milardović, S. & Grabarić, S. (2004) Palladium hexacyanoferrate hydrogel as novel and simple enzyme immobilization matrix for amperometric biosensors. Biosensors & bioelectronics, 20, 872-878.
@article{article, author = {Ivekovi\'{c}, Damir and Milardovi\'{c}, Stjepan and Grabari\'{c}, S. Bo\v{z}idar}, year = {2004}, pages = {872-878}, keywords = {Glucose biosensor, Glucose oxidase, Hydrogel, Nickel hexacyanoferrate, Amperometric}, journal = {Biosensors and bioelectronics}, volume = {20}, issn = {0956-5663}, title = {Palladium hexacyanoferrate hydrogel as novel and simple enzyme immobilization matrix for amperometric biosensors}, keyword = {Glucose biosensor, Glucose oxidase, Hydrogel, Nickel hexacyanoferrate, Amperometric} }
@article{article, author = {Ivekovi\'{c}, Damir and Milardovi\'{c}, Stjepan and Grabari\'{c}, S. Bo\v{z}idar}, year = {2004}, pages = {872-878}, keywords = {Glucose biosensor, Glucose oxidase, Hydrogel, Nickel hexacyanoferrate, Amperometric}, journal = {Biosensors and bioelectronics}, volume = {20}, issn = {0956-5663}, title = {Palladium hexacyanoferrate hydrogel as novel and simple enzyme immobilization matrix for amperometric biosensors}, keyword = {Glucose biosensor, Glucose oxidase, Hydrogel, Nickel hexacyanoferrate, Amperometric} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • Chemical Abstracts
  • Agricola
  • Biosis
  • Embase
  • Cambrige Scientific Abstract
  • Pollution Abstract





Contrast
Increase Font
Decrease Font
Dyslexic Font