Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 16502

A custom designed system to measure the corticospinal tract jitter


Mihelin, Marjan; Liščić, Rajka M.
A custom designed system to measure the corticospinal tract jitter // Electroencephalography and clinical neurophysiology : electromyography and motor control, 109 (1998), 2; 194-197 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 16502 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
A custom designed system to measure the corticospinal tract jitter

Autori
Mihelin, Marjan ; Liščić, Rajka M.

Izvornik
Electroencephalography and clinical neurophysiology : electromyography and motor control (0924-980X) 109 (1998), 2; 194-197

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
motor unit responses; magnetic stimulation; EMG responses; muscle; cortex; brain
(motor unit responses; magnetic stimulation; EMG responses. muscle; cortex; brain)

Sažetak
Typical latency of an individual limb muscle response to magnetic or electric stimulation of the human cortex is in the range of 10-50 ms. For the latency varaiability, i.e., jitter studies, a resulution of at least 20 us is needed. Commercially available EMG equipment needs custom-designed upgrading to allow for such studies. Two solutions were designed: (i) a hardware unit allowing an adjustable delay of data acquisition after the delivered stimuli; and (ii) diverting of the amplified biological signal and the EMG equipment trigger to an external computer equipped with an analogue-to-digital conversion (ADC) module. Custom-designed software made fast ADC possible during the whole period of data acquisition. both concepts were applied to a Vickers Medical Mystro electromyograph, and have been succesfully used in the Ljubljana (Slovenia) Institute of Clinical Neurophysiology for the last two years.

Izvorni jezik
Engleski

Znanstvena područja
Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Projekti:
00220302

Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb

Profili:

Avatar Url Rajka Liščić (autor)


Citiraj ovu publikaciju:

Mihelin, Marjan; Liščić, Rajka M.
A custom designed system to measure the corticospinal tract jitter // Electroencephalography and clinical neurophysiology : electromyography and motor control, 109 (1998), 2; 194-197 (međunarodna recenzija, članak, znanstveni)
Mihelin, M. & Liščić, R. (1998) A custom designed system to measure the corticospinal tract jitter. Electroencephalography and clinical neurophysiology : electromyography and motor control, 109 (2), 194-197.
@article{article, author = {Mihelin, Marjan and Li\v{s}\v{c}i\'{c}, Rajka M.}, year = {1998}, pages = {194-197}, keywords = {motor unit responses, magnetic stimulation, EMG responses, muscle, cortex, brain}, journal = {Electroencephalography and clinical neurophysiology : electromyography and motor control}, volume = {109}, number = {2}, issn = {0924-980X}, title = {A custom designed system to measure the corticospinal tract jitter}, keyword = {motor unit responses, magnetic stimulation, EMG responses, muscle, cortex, brain} }
@article{article, author = {Mihelin, Marjan and Li\v{s}\v{c}i\'{c}, Rajka M.}, year = {1998}, pages = {194-197}, keywords = {motor unit responses, magnetic stimulation, EMG responses. muscle, cortex, brain}, journal = {Electroencephalography and clinical neurophysiology : electromyography and motor control}, volume = {109}, number = {2}, issn = {0924-980X}, title = {A custom designed system to measure the corticospinal tract jitter}, keyword = {motor unit responses, magnetic stimulation, EMG responses. muscle, cortex, brain} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • Excerpta medica





Contrast
Increase Font
Decrease Font
Dyslexic Font