Transient charge deposition and electric stress in HV GIS


Hot, Kemal; Kelemen, Tomislav
Transient charge deposition and electric stress in HV GIS // Proceedings of the XIIIth International Syimposium on Hogh Voltage Engineering, Delft, Netherlands / Smit, j. Johan (ur.).
Rotterdam : Boston (MA) : Taipei: Millpress Rotterdam, 2003. str. 1-4 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 157150 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Transient charge deposition and electric stress in HV GIS

Autori
Hot, Kemal ; Kelemen, Tomislav

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the XIIIth International Syimposium on Hogh Voltage Engineering, Delft, Netherlands / Smit, j. Johan - Rotterdam : Boston (MA) : Taipei : Millpress Rotterdam, 2003, 1-4

Skup
High Voltage Engineering

Mjesto i datum
Delft, Nizozemska, 25.08.2003. - 29.08.2003

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Gas insulated substation; ion charge transfer; charge distribution; field distorsion

Sažetak
High voltage insulator in a typical GIS (gas insulated substation) was considered to withstand DC electrical stress that cause the ion charge transfer. The field distribution across insulator with long creepage paths and field distortion due to the deposition of charge on the insulator surface was calculated on a geometry model by finite element techniques. The applied voltage was a standard surge wave and the final charge distribution was calculated. The gas ionization and the charge transfer to insulator were dependent on the changing electric field between the busbar and the insulator concave surface. Overcritical value of electric field at busbar surface were used in calculation of electron emission at cold cathode conditions. The results of field analysis were verified by standard measurements on 110 kV insulators in real scale GIS compartment.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0008001

Profili:

Avatar Url Kemal Hot (autor)

Avatar Url Tomislav Kelemen (autor)


Citiraj ovu publikaciju:

Hot, Kemal; Kelemen, Tomislav
Transient charge deposition and electric stress in HV GIS // Proceedings of the XIIIth International Syimposium on Hogh Voltage Engineering, Delft, Netherlands / Smit, j. Johan (ur.).
Rotterdam : Boston (MA) : Taipei: Millpress Rotterdam, 2003. str. 1-4 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Hot, K. & Kelemen, T. (2003) Transient charge deposition and electric stress in HV GIS. U: Smit, j. (ur.)Proceedings of the XIIIth International Syimposium on Hogh Voltage Engineering, Delft, Netherlands.
@article{article, author = {Hot, Kemal and Kelemen, Tomislav}, editor = {Smit, j.}, year = {2003}, pages = {1-4}, keywords = {Gas insulated substation, ion charge transfer, charge distribution, field distorsion}, title = {Transient charge deposition and electric stress in HV GIS}, keyword = {Gas insulated substation, ion charge transfer, charge distribution, field distorsion}, publisher = {Millpress Rotterdam}, publisherplace = {Delft, Nizozemska} }
@article{article, author = {Hot, Kemal and Kelemen, Tomislav}, editor = {Smit, j.}, year = {2003}, pages = {1-4}, keywords = {Gas insulated substation, ion charge transfer, charge distribution, field distorsion}, title = {Transient charge deposition and electric stress in HV GIS}, keyword = {Gas insulated substation, ion charge transfer, charge distribution, field distorsion}, publisher = {Millpress Rotterdam}, publisherplace = {Delft, Nizozemska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font