Pregled bibliografske jedinice broj: 154896
Landslide at the Jakusevec landfill
Landslide at the Jakusevec landfill // Geotechnical Engineering with Geosynthetics / Floss, Rudolf ; Brau, Gerhard ; Nussbaumer, Manfred ; Laackmann, Kirsten (ur.).
München: DGGT, 2004. str. 87-92 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), stručni)
CROSBI ID: 154896 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Landslide at the Jakusevec landfill
Autori
Vukelić, Ana ; Kovačević Zelić, Biljana ; Drnjević, Branimir
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), stručni
Izvornik
Geotechnical Engineering with Geosynthetics
/ Floss, Rudolf ; Brau, Gerhard ; Nussbaumer, Manfred ; Laackmann, Kirsten - München : DGGT, 2004, 87-92
Skup
EUROGEO'3 - Third European Geosynthetics Conference
Mjesto i datum
München, Njemačka, 01.03.2004. - 03.03.2004
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
landfill; landslide; geosynthetics; stability
Sažetak
The dumpsite remediation at the Jakusevec Landfill is performed by relocating old waste onto rehabilitated cells which bottom is comprised of the liner (clay and textured geomembrane) above which the protective geotextile, drainage gravel and filter geotextile are placed. In August 2002 a locally contained slide was noticed at a section of the rehabilitated landfill formed at the bottom of the relocated waste slope surface. In order to establish what caused the slide, laboratory shear tests at the fully saturated clay/geomembrane interface were carried out, as well as field investigations regarding the construction of three wells in the area of large displacements. Furthermore, back analyses were also carried out which have established waste and bottom liner shear strength parameters for the safety factors of approximately 1.0. Based on the results of investigation works and performed analyses, it has been established that the slide occurred due to a decrease in the waste and bottom liner shear strength. In the end, recommendations are given for designing and construction that would reduce the risk of similar slides at landfills.
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo, Rudarstvo, nafta i geološko inženjerstvo
POVEZANOST RADA
Projekti:
0195033
Ustanove:
INSTITUT IGH, d.d.,
Rudarsko-geološko-naftni fakultet, Zagreb