Concentration-Dependent Proton Magnetic Cross Relaxation in Aqueous Polyoxyethylene Solutions
Concentration-Dependent Proton Magnetic Cross Relaxation in Aqueous Polyoxyethylene Solutions // The journal of physical chemistry. A, Molecules, spectroscopy, kinetics, environment, & general theory, 84 (1980), 913-916 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 153576 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Concentration-Dependent Proton Magnetic Cross Relaxation in Aqueous Polyoxyethylene Solutions
Autori
Benko, Bojan ; Buljan, Vlado ; Vuk-Pavlović, Stanimir
Izvornik
The journal of physical chemistry. A, Molecules, spectroscopy, kinetics, environment, & general theory (1089-5639) 84
(1980);
913-916
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Cross-relaxation; Hydratation; Polyethyleneglycol; Polyoxyethylene; Proton magnetic relaxation
Sažetak
Longitudinal proton magnetic relaxation rates were measured in aqueous solutions of polyoxyethylene (POE) 400 as a function of the polymer concentration. At all concentrations the plot of reduced magnetization vs. pulse separation in 180°- t - 90° sequence yields a nonlinear line which is easily separated into two relaxation processes. Both relaxation rates increase faster with the concentration above 50% POE than below. Above this concentration, the fractions of z magnetization ascribed to each of two relaxation phases deviate from the values expected from the chemical composition of the solution. This demonstrates the transfer of magnetization between these phases, i.e., the cross-relaxation phenomenon. The relaxation rates of POE and water protons in the absence of cross relaxation, the cross-relaxation rates, and the normalized intensities of the relaxation components for each of the relaxation phases were computed according to Edzes and Samulski after modifications required by the specificities of the POE-water system. According to the present data, along with those from literature, it is concluded that polymer ordering within the aqueous solution take place above 50% POE, providing thus a structural basis for the apparent cross-relaxation phenomenon.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Kemija, Biologija
POVEZANOST RADA
Ustanove:
Imunološki zavod d.d.
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- SCI-EXP, SSCI i/ili A&HCI
Uključenost u ostale bibliografske baze podataka::
- Chemical Abstracts