Pregled bibliografske jedinice broj: 146060
Conversion Rate in Composite Samples Cured with Different LED Sources
Conversion Rate in Composite Samples Cured with Different LED Sources // Journal of Dental Research, 83 (2004), special issue A. (podatak o recenziji nije dostupan, kongresno priopcenje, znanstveni)
CROSBI ID: 146060 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Conversion Rate in Composite Samples Cured with Different LED Sources
Autori
Meniga, Andrej ; Tarle, Zrinka ; Knežević, Alena ; Šutalo, Jozo ; Pichler, Goran
Izvornik
Journal of Dental Research (0022-0345) 83
(2004), Special issue A;
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, kongresno priopcenje, znanstveni
Ključne riječi
degree of conversion; LED; composite resins
Sažetak
Objectives: The trend of using high power curing lights switched to more gentle light source - LED (light emitting diode) units which enabled lesser shrinkage stress for tooth structure. At the same time polymerization process needs adequate intensity and illumination time to properly cure the composite resin layer in clinical situation. Methods: Five specimen of 10 mm diameter A3 shade composite restorative Filtek Z 250 (3M ESPE), was illuminated for 40 sec by Lux-o-Max (Akeda Dental), and 20 sec for Elipar Freelight I (3M ESPE), L.E.Demetron (Kerr) and halogen unit Elipar Trilight (3M ESPE) as a control. The degree of conversion was measured by FTIR spectroscope at the sample surface and at the 2 mm depth using previously cured underlays and overlays. The degree of conversion was calculated from the equivalent aliphatic/aromatic molar ratio between polymerized and unpolymerized samples. Results: Low intensity LED curing unit show 52.86 % (sd 1.59) conversion at the surface and 46.91% (sd 5.21) at 2 mm depth. Monomer conversion with medium intensity LED unit was 58.31% (sd 0.11) and 54.04% (sd 1.27). The results with second generation LED curing unit were 66.55% (sd 5.76) and 66.72 (sd 4.8) at 2 mm depth which is better than with control unit - 63.51% (sd 2.29) and 54.61% (sd 2.23) respectively. Conclusion: The measurements reveal that with first generation LED's curing time must be prolongued to achieve clinically acceptable composite filling even with high photosensitive resin. Medium intensity unit show better overal conversion especially at 2 mm depth. High output second generation LED unit showed no difference in conversion between layers, but the shrinkage stress may be high.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Dentalna medicina
POVEZANOST RADA
Ustanove:
Institut za fiziku, Zagreb,
Stomatološki fakultet, Zagreb
Profili:
Zrinka Tarle
(autor)
Andrej Meniga
(autor)
Goran Pichler
(autor)
Jozo Šutalo
(autor)
Alena Knežević
(autor)