Pregled bibliografske jedinice broj: 144185

TLD-700 for proton dosimetry in presence of low energy X-rays


Miljanić, Saveta; Ranogajec-Komor, Maria; Blagus, Saša; Miljanić, Đuro; Osvay, M.
TLD-700 for proton dosimetry in presence of low energy X-rays // Nuclear Instruments and Methods in Physics Research. Section A, 519 (2004), 667-673 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 144185 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
TLD-700 for proton dosimetry in presence of low energy X-rays

Autori
Miljanić, Saveta ; Ranogajec-Komor, Maria ; Blagus, Saša ; Miljanić, Đuro ; Osvay, M.

Izvornik
Nuclear Instruments and Methods in Physics Research. Section A (0168-9002) 519 (2004); 667-673

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Proton dosimetry; Thermoluminescence dosimeters; TLD-700; CaF2:Mn; TL efficiency

Sažetak
The results of TLD-700 irradiations with 3 MeV protons using Tandem Van de Graaff accelerator are shown. In order to estimate the contribution of X-rays, CaF_2:Mn TL detectors were also irradiated at the same condition as TLD-700. Due to the presence of low energy X-rays, the peak area method of high-temperature peak 7 of TLD-700 was found to be more suitable for proton dose determination. TL efficiency for protons using this peak relatively to ^137Cs gamma rays was calculated. The relative responses (peak 7)_p/(peak 5)_gamma and (peak 7)_p/(peak 7)_gamma of 0.16 and 9.6, respectively were obtained. Taking into account the self-absorption of the TL photons in the dosimeter the relative efficiency for peak 7, ni_p, gamma, = 8.0 was found.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kemija



POVEZANOST RADA


Projekti:
0098063
0098008

Ustanove:
Institut "Ruđer Bošković", Zagreb


Citiraj ovu publikaciju:

Miljanić, Saveta; Ranogajec-Komor, Maria; Blagus, Saša; Miljanić, Đuro; Osvay, M.
TLD-700 for proton dosimetry in presence of low energy X-rays // Nuclear Instruments and Methods in Physics Research. Section A, 519 (2004), 667-673 (međunarodna recenzija, članak, znanstveni)
Miljanić, S., Ranogajec-Komor, M., Blagus, S., Miljanić, Đ. & Osvay, M. (2004) TLD-700 for proton dosimetry in presence of low energy X-rays. Nuclear Instruments and Methods in Physics Research. Section A, 519, 667-673.
@article{article, author = {Miljani\'{c}, Saveta and Ranogajec-Komor, Maria and Blagus, Sa\v{s}a and Miljani\'{c}, \DJuro and Osvay, M.}, year = {2004}, pages = {667-673}, keywords = {Proton dosimetry, Thermoluminescence dosimeters, TLD-700, CaF2:Mn, TL efficiency}, journal = {Nuclear Instruments and Methods in Physics Research. Section A}, volume = {519}, issn = {0168-9002}, title = {TLD-700 for proton dosimetry in presence of low energy X-rays}, keyword = {Proton dosimetry, Thermoluminescence dosimeters, TLD-700, CaF2:Mn, TL efficiency} }
@article{article, author = {Miljani\'{c}, Saveta and Ranogajec-Komor, Maria and Blagus, Sa\v{s}a and Miljani\'{c}, \DJuro and Osvay, M.}, year = {2004}, pages = {667-673}, keywords = {Proton dosimetry, Thermoluminescence dosimeters, TLD-700, CaF2:Mn, TL efficiency}, journal = {Nuclear Instruments and Methods in Physics Research. Section A}, volume = {519}, issn = {0168-9002}, title = {TLD-700 for proton dosimetry in presence of low energy X-rays}, keyword = {Proton dosimetry, Thermoluminescence dosimeters, TLD-700, CaF2:Mn, TL efficiency} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus





Contrast
Increase Font
Decrease Font
Dyslexic Font