Pregled bibliografske jedinice broj: 1427
The frequency distribution of the number of ion pairs in irradiated tissue
The frequency distribution of the number of ion pairs in irradiated tissue // Radiation research, 149 (1998), 5; 411-415 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1427 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The frequency distribution of the number of ion pairs in irradiated tissue
Autori
Obelić, Bogomil ; Srdoč, Dušan ; Djurić, P.M. ; Marino, S.A.
Izvornik
Radiation research (0033-7587) 149
(1998), 5;
411-415
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
microdosimetry; number of ion pairs; proportional counter; primary distribution; deconvolution; tissue equivalent counter
Sažetak
The statistical distribution of the number of ion pairs per ionizing event in a small volume simulating a tissue sphere was obtained by applying the Expectation-Maximization (EM) algorithm to experimental spectra measured by exposing a Rossi-type spherical proportional counter to gamma radiation. The normalized experimental spectrum, r(x), which is the distribution of the number of ion pairs per event from both the primary track and the subsequent electron multiplication, can be represented as , where the f(n, x)"s for n=1, 2, 3, ..., n are the normalized spectra for exactly 1, 2, 3, ..., n primary ion pairs and are calculated by convoluting the single-electron spectrum. The coefficients pn represent the mixing proportions of the spectra corresponding to 1, 2, 3, ..., n ion pairs in forming the experimental spectrum. The single-electron spectrum used in our calculations is the distribution of the number of ion pairs due to the multiplication process and is represented in analytic form by the Gamma distribution , where x is energy, usually in eV, and a, b and c are constants. The EM algorithm is an iterative procedure for computing the maximum likelihood or maximum a posteriori estimates of the mixing proportions pn, which we also refer to as primary distribution of ion pairs in a microscopic spherical tissue-equivalent volume. The experimental and primary spectra are presented for simulated tissue spheres ranging from 0.25 to 8 ľm in diameter exposed to 60Co gamma radiation.
Izvorni jezik
Engleski
Znanstvena područja
Fizika
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE