Pregled bibliografske jedinice broj: 139808
Real Amplifier Influence on Impedance Tapered 2nd-Order Filters
Real Amplifier Influence on Impedance Tapered 2nd-Order Filters // Proceedings of the Region 8-IEEE International Conference on Computer as a Tool (EUROCON 2003). Vol. 1 / Zajc, Baldomir ; Tkalčić, Marko (ur.).
Ljubljana: IEEE Region 8, Slovenia Section, 2003. str. 110-113 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 139808 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Real Amplifier Influence on Impedance Tapered 2nd-Order Filters
Autori
Stojković, Nino ; Jurišić, Dražen ; Mijat, Neven
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the Region 8-IEEE International Conference on Computer as a Tool (EUROCON 2003). Vol. 1
/ Zajc, Baldomir ; Tkalčić, Marko - Ljubljana : IEEE Region 8, Slovenia Section, 2003, 110-113
ISBN
0-7803-7763-X
Skup
Region IEEE International Conference on Computer )as a Tool (8 ; 2003
Mjesto i datum
Ljubljana, Slovenija, 02.02.2003. - 24.09.2003
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
active-RC filters; active sensitivity; passive sensitivity; impedance tapering
Sažetak
In this paper, an influence of real parameters of operational amplifier to the impedance tapered filter transfer function is analyzed. As an example, a second-order low-pass (LP) and high-pass (HP) Sallen and Key filters with Butterworth and Chebyshev transfer function approximations are considered. Design tables with normalized element values for both cases are given. The filter elements were calculated using three different design criteria: equal resistors, capacitors and impedance tapered elements. Filter transfer functions are obtained using ideal and real operational amplifier. Real model of common operational amplifier is presented. Active sensitivities for all presented filters are shown. The results obtained by the analyses show significant influence of real amplifier in the frequency ranges higher than 100kHz. Reduction of active sensitivities is obtained using impedance tapering, which fortunately, reduces the passive sensitivities as well.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika, Računarstvo
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
Tehnički fakultet, Rijeka