Influence of DVM's input parameters on DVM-based high-ohm resistance comparison


Leniček, Ivan
Influence of DVM's input parameters on DVM-based high-ohm resistance comparison // Proceedings of the 12th IMEKO TC4 International Symposium Electrical Measurements and Instrumentation, Part 1 / Ilić, Damir ; Boršić, Mladen ; Butorac, Josip (ur.).
Zagreb: Hrvatsko mjeriteljsko društvo, 2002. str. 91-95 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 138985 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Influence of DVM's input parameters on DVM-based high-ohm resistance comparison

Autori
Leniček, Ivan

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 12th IMEKO TC4 International Symposium Electrical Measurements and Instrumentation, Part 1 / Ilić, Damir ; Boršić, Mladen ; Butorac, Josip - Zagreb : Hrvatsko mjeriteljsko društvo, 2002, 91-95

Skup
IMEKO TC4 International Symposium Electrical Measurements and Instrumentation

Mjesto i datum
Zagreb, Hrvatska, 25.09.2002. - 27.09.2002

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
high-ohm resistance comparison; DVM's input parameters

Sažetak
Establishment and maintenance of resistance standard traceability is one of the main tasks of Primary Electromagnetic Laboratory (PEL) within the Faculty of Electrical Engineering and Computing of the University of Zagreb. For the purpose of accurate resistance standards comparison a digital voltmeter (DVM) based method has been designed and realized. When measuring resistance standards greater than 10 Mohm capabilities of the method are restricted due to influence of DVM's input parameters: input DVM's resistance, input offset current and input capacitance. Determination of DVM's input parameters and their contribution to the overall high-ohm resistance comparison uncertainty has been presented in this paper. The possibility of use of DVM-based method for gigaohm value resistors comparison has also been investigated.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0036042

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Ivan Leniček (autor)


Citiraj ovu publikaciju:

Leniček, Ivan
Influence of DVM's input parameters on DVM-based high-ohm resistance comparison // Proceedings of the 12th IMEKO TC4 International Symposium Electrical Measurements and Instrumentation, Part 1 / Ilić, Damir ; Boršić, Mladen ; Butorac, Josip (ur.).
Zagreb: Hrvatsko mjeriteljsko društvo, 2002. str. 91-95 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Leniček, I. (2002) Influence of DVM's input parameters on DVM-based high-ohm resistance comparison. U: Ilić, D., Boršić, M. & Butorac, J. (ur.)Proceedings of the 12th IMEKO TC4 International Symposium Electrical Measurements and Instrumentation, Part 1.
@article{article, author = {Leni\v{c}ek, Ivan}, year = {2002}, pages = {91-95}, keywords = {high-ohm resistance comparison, DVM and \#39, s input parameters}, title = {Influence of DVM and \#39;s input parameters on DVM-based high-ohm resistance comparison}, keyword = {high-ohm resistance comparison, DVM and \#39, s input parameters}, publisher = {Hrvatsko mjeriteljsko dru\v{s}tvo}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {Leni\v{c}ek, Ivan}, year = {2002}, pages = {91-95}, keywords = {high-ohm resistance comparison, DVM and \#39, s input parameters}, title = {Influence of DVM and \#39;s input parameters on DVM-based high-ohm resistance comparison}, keyword = {high-ohm resistance comparison, DVM and \#39, s input parameters}, publisher = {Hrvatsko mjeriteljsko dru\v{s}tvo}, publisherplace = {Zagreb, Hrvatska} }