Pregled bibliografske jedinice broj: 1291
Determination of Stray Losses in Squirrel-cage Induction Motor Due to Converter Supply from Measurements in No-load Operation
Determination of Stray Losses in Squirrel-cage Induction Motor Due to Converter Supply from Measurements in No-load Operation // Proceedings 9th EDPE The 9th International Conference-Electrical Drives and Power Electronics / Ban, Drago ; Benčić, Zvonko (ur.).
Zagreb: Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA), 1996. str. 212-215 (predavanje, domaća recenzija, cjeloviti rad (in extenso), stručni)
CROSBI ID: 1291 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Determination of Stray Losses in Squirrel-cage Induction Motor Due to Converter Supply from Measurements in No-load Operation
Autori
Kurtović, Ivan ; Štefanko, Stjepan ; Bogut, Marijan
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), stručni
Izvornik
Proceedings 9th EDPE The 9th International Conference-Electrical Drives and Power Electronics
/ Ban, Drago ; Benčić, Zvonko - Zagreb : Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA), 1996, 212-215
Skup
The 9th International Conference-Electrical Drives and Power Electronics
Mjesto i datum
Dubrovnik, Hrvatska, 09.10.1996. - 11.10.1996
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Domaća recenzija
Ključne riječi
induction motor; converter supply; losses; measurements
Sažetak
Methods for determination of stray losses in converter-driven squirrel-cage induction motor at rated operation from results of no-load measurements are analysed. The computed and the measured values of losses are compared for the fundamental frequency of 50 Hz.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika