Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1283138

Large area silicon drift detectors system for high precision timed x-ray spectroscopy


Miliucci, M; Iliescu, M; Sgaramella, F; Bazzi, M; Bosnar, D; Bragadireanu, M; Carminati, M; Cargnelli, M; Clozza, A; Curceanu, C et al.
Large area silicon drift detectors system for high precision timed x-ray spectroscopy // Measurement science & technology, 33 (2022), 9; 095502, 10 doi:10.1088/1361-6501/ac777a (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1283138 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Large area silicon drift detectors system for high precision timed x-ray spectroscopy

Autori
Miliucci, M ; Iliescu, M ; Sgaramella, F ; Bazzi, M ; Bosnar, D ; Bragadireanu, M ; Carminati, M ; Cargnelli, M ; Clozza, A ; Curceanu, C ; Deda, G ; De Paolis, L ; Del Grande, R ; Fiorini, C ; Guaraldo, C ; Iwasaki, M ; King, P ; Levi Sandri, P ; Marton, J ; Moskal, P ; Napolitano, F ; Niedźwiecki, S ; Piscicchia, K ; Scordo, A ; Shi, H ; Silarski, M ; Sirghi, D ; Sirghi, F ; Skurzok, M ; Spallone, A ; Tüchler, M ; Vazquez Doce, O ; Zmeskal, J

Izvornik
Measurement science & technology (0957-0233) 33 (2022), 9; 095502, 10

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
silicon drift detector ; x-ray spectroscopy ; charge dynamics ; timing response ; energy response

Sažetak
The current work presents the optimization of large area silicon drift detectors developed by the SIDDHARTA-2 collaboration for high precision x-ray measurements of light exotic atom transitions. Two different radiation sources were employed in the study: an x-ray tube, for investigating the energy resolution and the charge collection efficiency of the device in the range 4000 eV–13 000 eV, and a β − 90Sr radioactive source for measuring the timing response, thus qualifying the charge drift parameters inside the semiconductor. The study reports the spectroscopic response optimization, together with the tuning of the electron dynamics for the given Silicon technology, by adjusting the applied electric field and the working temperature, which allow a good control of the device’s performances for high precision, timed x-ray spectroscopy applications.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
HRZZ-IP-2018-01-8570 - Elektroni, kaoni i neutroni u preciznim mjerenjima svojstava hadrona i jezgara (EKNpEXP) (Bosnar, Damir, HRZZ - 2018-01) ( CroRIS)

Ustanove:
Prirodoslovno-matematički fakultet, Zagreb

Profili:

Avatar Url Damir Bosnar (autor)

Poveznice na cjeloviti tekst rada:

doi iopscience.iop.org

Citiraj ovu publikaciju:

Miliucci, M; Iliescu, M; Sgaramella, F; Bazzi, M; Bosnar, D; Bragadireanu, M; Carminati, M; Cargnelli, M; Clozza, A; Curceanu, C et al.
Large area silicon drift detectors system for high precision timed x-ray spectroscopy // Measurement science & technology, 33 (2022), 9; 095502, 10 doi:10.1088/1361-6501/ac777a (međunarodna recenzija, članak, znanstveni)
Miliucci, M., Iliescu, M., Sgaramella, F., Bazzi, M., Bosnar, D., Bragadireanu, M., Carminati, M., Cargnelli, M., Clozza, A. & Curceanu, C. (2022) Large area silicon drift detectors system for high precision timed x-ray spectroscopy. Measurement science & technology, 33 (9), 095502, 10 doi:10.1088/1361-6501/ac777a.
@article{article, author = {Miliucci, M and Iliescu, M and Sgaramella, F and Bazzi, M and Bosnar, D and Bragadireanu, M and Carminati, M and Cargnelli, M and Clozza, A and Curceanu, C and Deda, G and De Paolis, L and Del Grande, R and Fiorini, C and Guaraldo, C and Iwasaki, M and King, P and Levi Sandri, P and Marton, J and Moskal, P and Napolitano, F and Nied\'{z}wiecki, S and Piscicchia, K and Scordo, A and Shi, H and Silarski, M and Sirghi, D and Sirghi, F and Skurzok, M and Spallone, A and T\"{u}chler, M and Vazquez Doce, O and Zmeskal, J}, year = {2022}, pages = {10}, DOI = {10.1088/1361-6501/ac777a}, chapter = {095502}, keywords = {silicon drift detector, x-ray spectroscopy, charge dynamics, timing response, energy response}, journal = {Measurement science and technology}, doi = {10.1088/1361-6501/ac777a}, volume = {33}, number = {9}, issn = {0957-0233}, title = {Large area silicon drift detectors system for high precision timed x-ray spectroscopy}, keyword = {silicon drift detector, x-ray spectroscopy, charge dynamics, timing response, energy response}, chapternumber = {095502} }
@article{article, author = {Miliucci, M and Iliescu, M and Sgaramella, F and Bazzi, M and Bosnar, D and Bragadireanu, M and Carminati, M and Cargnelli, M and Clozza, A and Curceanu, C and Deda, G and De Paolis, L and Del Grande, R and Fiorini, C and Guaraldo, C and Iwasaki, M and King, P and Levi Sandri, P and Marton, J and Moskal, P and Napolitano, F and Nied\'{z}wiecki, S and Piscicchia, K and Scordo, A and Shi, H and Silarski, M and Sirghi, D and Sirghi, F and Skurzok, M and Spallone, A and T\"{u}chler, M and Vazquez Doce, O and Zmeskal, J}, year = {2022}, pages = {10}, DOI = {10.1088/1361-6501/ac777a}, chapter = {095502}, keywords = {silicon drift detector, x-ray spectroscopy, charge dynamics, timing response, energy response}, journal = {Measurement science and technology}, doi = {10.1088/1361-6501/ac777a}, volume = {33}, number = {9}, issn = {0957-0233}, title = {Large area silicon drift detectors system for high precision timed x-ray spectroscopy}, keyword = {silicon drift detector, x-ray spectroscopy, charge dynamics, timing response, energy response}, chapternumber = {095502} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font