Uninterruptible Power Supply System for Railway Infrastructure with Power Factor Correction and Immunity to Energy Strike


Hećimović, Ante; Patrlj, Leo; Šunde, Viktor; Ban, Željko
Uninterruptible Power Supply System for Railway Infrastructure with Power Factor Correction and Immunity to Energy Strike // MIPRO 2023 46th ICT and Electronics Convention / Skala, Karolj (ur.).
Rijeka: Hrvatska udruga za informacijsku i komunikacijsku tehnologiju, elektroniku i mikroelektroniku - MIPRO, 2023. str. 275-280 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 1281368 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Uninterruptible Power Supply System for Railway Infrastructure with Power Factor Correction and Immunity to Energy Strike

Autori
Hećimović, Ante ; Patrlj, Leo ; Šunde, Viktor ; Ban, Željko

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
MIPRO 2023 46th ICT and Electronics Convention / Skala, Karolj - Rijeka : Hrvatska udruga za informacijsku i komunikacijsku tehnologiju, elektroniku i mikroelektroniku - MIPRO, 2023, 275-280

Skup
MIPRO 2023 46th ICT and Electronics Convention

Mjesto i datum
Opatija, Hrvatska, 22.05.2023. - 26.05.2023

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Uninterrupted Power Supply (UPS), Power Factor Correction (PFC), overvoltage protection, railway power supply system

Sažetak
This article deals with an uninterruptible power supply (UPS) for infrastructure equipment used in the railway system. The main feature of this UPS is the high power factor and resistance to overvoltages that occur in the railway network. Power factor correction (PFC) is done by adding a boost DC converter. The resistance to overvoltages is achieved by means of protective elements, i.e. varistors, and inductors, as well as an additional overvoltage detection in the power supply network. Based on the output of the mentioned device, the part of the topology intended for power factor correction can be switched off.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
EK-EFRR-KK.01.2.1.02.0193 - Razvoj robusnog sustava neprekinutog napajanja za uređaje željezničke i industrijske infrastrukture otpornog na naponske smetnje 25 kV ili drugog visokonaponskog napojnog voda (Mareton-2) (Ban, Željko, EK ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Željko Ban (autor)

Avatar Url Viktor Šunde (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Hećimović, Ante; Patrlj, Leo; Šunde, Viktor; Ban, Željko
Uninterruptible Power Supply System for Railway Infrastructure with Power Factor Correction and Immunity to Energy Strike // MIPRO 2023 46th ICT and Electronics Convention / Skala, Karolj (ur.).
Rijeka: Hrvatska udruga za informacijsku i komunikacijsku tehnologiju, elektroniku i mikroelektroniku - MIPRO, 2023. str. 275-280 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Hećimović, A., Patrlj, L., Šunde, V. & Ban, Ž. (2023) Uninterruptible Power Supply System for Railway Infrastructure with Power Factor Correction and Immunity to Energy Strike. U: Skala, K. (ur.)MIPRO 2023 46th ICT and Electronics Convention.
@article{article, author = {He\'{c}imovi\'{c}, Ante and Patrlj, Leo and \v{S}unde, Viktor and Ban, \v{Z}eljko}, editor = {Skala, K.}, year = {2023}, pages = {275-280}, keywords = {Uninterrupted Power Supply (UPS), Power Factor Correction (PFC), overvoltage protection, railway power supply system}, title = {Uninterruptible Power Supply System for Railway Infrastructure with Power Factor Correction and Immunity to Energy Strike}, keyword = {Uninterrupted Power Supply (UPS), Power Factor Correction (PFC), overvoltage protection, railway power supply system}, publisher = {Hrvatska udruga za informacijsku i komunikacijsku tehnologiju, elektroniku i mikroelektroniku - MIPRO}, publisherplace = {Opatija, Hrvatska} }
@article{article, author = {He\'{c}imovi\'{c}, Ante and Patrlj, Leo and \v{S}unde, Viktor and Ban, \v{Z}eljko}, editor = {Skala, K.}, year = {2023}, pages = {275-280}, keywords = {Uninterrupted Power Supply (UPS), Power Factor Correction (PFC), overvoltage protection, railway power supply system}, title = {Uninterruptible Power Supply System for Railway Infrastructure with Power Factor Correction and Immunity to Energy Strike}, keyword = {Uninterrupted Power Supply (UPS), Power Factor Correction (PFC), overvoltage protection, railway power supply system}, publisher = {Hrvatska udruga za informacijsku i komunikacijsku tehnologiju, elektroniku i mikroelektroniku - MIPRO}, publisherplace = {Opatija, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font