Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1281140

Post-blast residual static capacity of retrofitted reinforced concrete slabs


Jeleč, Mario; Draganić, Hrvoje; Gazić, Goran; Lukić, Sanja
Post-blast residual static capacity of retrofitted reinforced concrete slabs // Engineering structures, 286 (2023), 116161, 17 doi:10.1016/j.engstruct.2023.116161 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1281140 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Post-blast residual static capacity of retrofitted reinforced concrete slabs

Autori
Jeleč, Mario ; Draganić, Hrvoje ; Gazić, Goran ; Lukić, Sanja

Izvornik
Engineering structures (0141-0296) 286 (2023); 116161, 17

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Static bending test ; Field blast test ; Residual capacity ; Blast mitigation ; Glass fiber polymer

Sažetak
Laboratory static bending tests were carried out to determine post-blast residual load-bearing capacities of retrofitted and un-retrofitted RC slabs. Three different retrofit systems were previously devised to strengthen RC slabs on potential blast-induced damage. The retrofit systems consisted of impregnating epoxy resin with (1) one layer of glass woven fabric and (2) one and (3) two layers of chopped strand glass mat. The contribution to strength, stiffness, energy absorption and damage reduction of devised retrofit systems was evaluated during testing by measured deformations, displacements, and force capacities. The presented results indicate that all applied retrofit systems provided some blast mitigation level by enhancing RC slabs’ residual strength and stiffness capacity. However, the retrofit system consisted of two layers of chopped-strand glass mat made the highest contribution to strength preservation.

Izvorni jezik
Engleski

Znanstvena područja
Građevinarstvo



POVEZANOST RADA


Projekti:
HRZZ-UIP-2017-05-7041 - Otpornost stupova nadvožnjaka na djelovanje eksplozije (BLAST) (Draganić, Hrvoje, HRZZ ) ( CroRIS)

Ustanove:
Građevinski i arhitektonski fakultet Osijek

Profili:

Avatar Url Mario Jeleč (autor)

Avatar Url Sanja Lukić (autor)

Avatar Url Goran Gazić (autor)

Avatar Url Hrvoje Draganić (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Jeleč, Mario; Draganić, Hrvoje; Gazić, Goran; Lukić, Sanja
Post-blast residual static capacity of retrofitted reinforced concrete slabs // Engineering structures, 286 (2023), 116161, 17 doi:10.1016/j.engstruct.2023.116161 (međunarodna recenzija, članak, znanstveni)
Jeleč, M., Draganić, H., Gazić, G. & Lukić, S. (2023) Post-blast residual static capacity of retrofitted reinforced concrete slabs. Engineering structures, 286, 116161, 17 doi:10.1016/j.engstruct.2023.116161.
@article{article, author = {Jele\v{c}, Mario and Dragani\'{c}, Hrvoje and Gazi\'{c}, Goran and Luki\'{c}, Sanja}, year = {2023}, pages = {17}, DOI = {10.1016/j.engstruct.2023.116161}, chapter = {116161}, keywords = {Static bending test, Field blast test, Residual capacity, Blast mitigation, Glass fiber polymer}, journal = {Engineering structures}, doi = {10.1016/j.engstruct.2023.116161}, volume = {286}, issn = {0141-0296}, title = {Post-blast residual static capacity of retrofitted reinforced concrete slabs}, keyword = {Static bending test, Field blast test, Residual capacity, Blast mitigation, Glass fiber polymer}, chapternumber = {116161} }
@article{article, author = {Jele\v{c}, Mario and Dragani\'{c}, Hrvoje and Gazi\'{c}, Goran and Luki\'{c}, Sanja}, year = {2023}, pages = {17}, DOI = {10.1016/j.engstruct.2023.116161}, chapter = {116161}, keywords = {Static bending test, Field blast test, Residual capacity, Blast mitigation, Glass fiber polymer}, journal = {Engineering structures}, doi = {10.1016/j.engstruct.2023.116161}, volume = {286}, issn = {0141-0296}, title = {Post-blast residual static capacity of retrofitted reinforced concrete slabs}, keyword = {Static bending test, Field blast test, Residual capacity, Blast mitigation, Glass fiber polymer}, chapternumber = {116161} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font