Influence of gas composition on the accuracy of gas flow measurement using various experimental techniques - preliminary report


Pavlović, Berislav; Panić, Goran; Kozmar, Hrvoje
Influence of gas composition on the accuracy of gas flow measurement using various experimental techniques - preliminary report // Proceedings of the 34th International Scientific & Expert Meeting of Gas Professionals / Banovac, Eraldo ; Pudić, Dalibor (ur.).
Opatija: Hrvatska stručna udruga za plin (HSUP), 2019. str. 1-10 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), stručni)


CROSBI ID: 1277924 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Influence of gas composition on the accuracy of gas flow measurement using various experimental techniques - preliminary report
(Influence of gas composition on the accuracy of gas flow measurement using various experimental techniques - preliminary report)

Autori
Pavlović, Berislav ; Panić, Goran ; Kozmar, Hrvoje

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), stručni

Izvornik
Proceedings of the 34th International Scientific & Expert Meeting of Gas Professionals / Banovac, Eraldo ; Pudić, Dalibor - Opatija : Hrvatska stručna udruga za plin (HSUP), 2019, 1-10

ISBN
978-953-7501-16-7

Skup
34th International Scientific & Expert Meeting of Gas Professionals

Mjesto i datum
Opatija, Hrvatska, 08.05.2019. - 10.05.2019

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Gas flow ; gas composition ; systematic deviation ; total measurement uncertainty

Sažetak
The present study provides experimental results of the relative deviations of the gas flow meters that operate using various experimental techniques. The tests were performed with the diaphragm gas meters, ultrasonic gas meters and microthermal gas meters. Measurements were performed within the working range of the measuring devices using several working fluids, i.e. air, argon, nitrogen, helium, natural gas and propane-butane mixture. The scope was to obtain a possible influence of the gas composition variation on experimental results. Measurements were also performed to obtain a functional relation between the gas composition and the systematic deviation of the meters. Preliminary results for ultrasonic gas meters show systematic deviations in the range from -1.5% up to -1.8% when using the natural gas compared to the results obtained using the air. For the microthermal gas meters, the systematic deviation of +1, 5% up to 2, 0% was obtained when using the natural gas compared to results with the air as a working fluid. The results obtained using the microthermal gas meters with other fluids show possible significant systematic errors.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Hrvoje Kozmar (autor)

Avatar Url Berislav Pavlović (autor)


Citiraj ovu publikaciju:

Pavlović, Berislav; Panić, Goran; Kozmar, Hrvoje
Influence of gas composition on the accuracy of gas flow measurement using various experimental techniques - preliminary report // Proceedings of the 34th International Scientific & Expert Meeting of Gas Professionals / Banovac, Eraldo ; Pudić, Dalibor (ur.).
Opatija: Hrvatska stručna udruga za plin (HSUP), 2019. str. 1-10 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), stručni)
Pavlović, B., Panić, G. & Kozmar, H. (2019) Influence of gas composition on the accuracy of gas flow measurement using various experimental techniques - preliminary report. U: Banovac, E. & Pudić, D. (ur.)Proceedings of the 34th International Scientific & Expert Meeting of Gas Professionals.
@article{article, author = {Pavlovi\'{c}, Berislav and Pani\'{c}, Goran and Kozmar, Hrvoje}, year = {2019}, pages = {1-10}, keywords = {Gas flow, gas composition, systematic deviation, total measurement uncertainty}, isbn = {978-953-7501-16-7}, title = {Influence of gas composition on the accuracy of gas flow measurement using various experimental techniques - preliminary report}, keyword = {Gas flow, gas composition, systematic deviation, total measurement uncertainty}, publisher = {Hrvatska stru\v{c}na udruga za plin (HSUP)}, publisherplace = {Opatija, Hrvatska} }
@article{article, author = {Pavlovi\'{c}, Berislav and Pani\'{c}, Goran and Kozmar, Hrvoje}, year = {2019}, pages = {1-10}, keywords = {Gas flow, gas composition, systematic deviation, total measurement uncertainty}, isbn = {978-953-7501-16-7}, title = {Influence of gas composition on the accuracy of gas flow measurement using various experimental techniques - preliminary report}, keyword = {Gas flow, gas composition, systematic deviation, total measurement uncertainty}, publisher = {Hrvatska stru\v{c}na udruga za plin (HSUP)}, publisherplace = {Opatija, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font