Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1275390

The 2–2–2–20–20 concept for supraacetabular schanz screw insertion without additional radiography


Schwarz, A.M.; Hohenberger, G.M.; Grechenig, P.; Kerner, A.; Gänsslen, A.; Staresinic, M.; Bakota, B.
The 2–2–2–20–20 concept for supraacetabular schanz screw insertion without additional radiography // Injury, 52 (2021), S58-S62 doi:10.1016/j.injury.2020.07.039 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1275390 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The 2–2–2–20–20 concept for supraacetabular schanz screw insertion without additional radiography

Autori
Schwarz, A.M. ; Hohenberger, G.M. ; Grechenig, P. ; Kerner, A. ; Gänsslen, A. ; Staresinic, M. ; Bakota, B.

Izvornik
Injury (0020-1383) 52 (2021); S58-S62

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
none available

Sažetak
Purpose: Application of supraacetabular Schanz screws is usually performed under image intensifier guidance. The aim of this study was to perform it without imaging, with the hypothesis that, respecting anatomical landmarks, pre- and intraoperative fluoroscopy can be avoided. Material & methods: Insertion of the supra- acetabular Schanz screws was performed by two trauma surgery residents in a study sample of 14 human adult cadavers which had been embalmed by use of Thiel`s method. With cadavers placed in supine position, the anterior superior iliac spine (ASIS) was palpated. Starting from this landmark, 2 cm were measured in a distal and 2 cm in the medial direction. At this point, a 2 cm long oblique skin incision was performed. Through this approach, 150 mm Schanz screws were drilled bilaterally into the supra-acetabular corridor with an angulation of 20° to distal as well as 20° to medial. Following screw application, combined obturator oblique-outlet views (COOO) were taken bilaterally in each specimen by use of an Arcadis© Orbic 3D C-arm to prove the screw position. Six of the specimens underwent a 3D-CT-scan. Images were evaluated concerning correct screw positioning by a further traumatologist. Skin and subcutaneous tissues were removed in the ilioinguinal region and possible lesions to the lateral femoral cutaneous nerve (LFCN) or to the joint capsule were evaluated. Results: The sample consisted of eight pelves from female and six pelves from male cadavers. During radiographic evaluation of the COOO-scans (14 specimens) and the 3D-scans (6 specimens), the Schanz screws were placed inside the supra- acetabular corridor in all specimens (14/14). During dissections, no intracapsular screw placements or LFCN lesions were found. Conclusion: According to the described anatomical data, we defined a 2-2-2-20-20 concept, starting with a 2 cm skin incision 2 cm distal and 2 cm medial to the ASIS with a drill angulation of 20° inferior and 20° lateral orientation. Using this technique, all Schanz screws could be sufficiently inserted without intraprocedural x-ray imaging

Izvorni jezik
Engleski



POVEZANOST RADA


Profili:

Avatar Url Mario Starešinić (autor)

Avatar Url Antun Kerner (autor)

Avatar Url Boris Bakota (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Schwarz, A.M.; Hohenberger, G.M.; Grechenig, P.; Kerner, A.; Gänsslen, A.; Staresinic, M.; Bakota, B.
The 2–2–2–20–20 concept for supraacetabular schanz screw insertion without additional radiography // Injury, 52 (2021), S58-S62 doi:10.1016/j.injury.2020.07.039 (međunarodna recenzija, članak, znanstveni)
Schwarz, A., Hohenberger, G., Grechenig, P., Kerner, A., Gänsslen, A., Staresinic, M. & Bakota, B. (2021) The 2–2–2–20–20 concept for supraacetabular schanz screw insertion without additional radiography. Injury, 52, S58-S62 doi:10.1016/j.injury.2020.07.039.
@article{article, author = {Schwarz, A.M. and Hohenberger, G.M. and Grechenig, P. and Kerner, A. and G\"{a}nsslen, A. and Staresinic, M. and Bakota, B.}, year = {2021}, pages = {S58-S62}, DOI = {10.1016/j.injury.2020.07.039}, keywords = {none available}, journal = {Injury}, doi = {10.1016/j.injury.2020.07.039}, volume = {52}, issn = {0020-1383}, title = {The 2–2–2–20–20 concept for supraacetabular schanz screw insertion without additional radiography}, keyword = {none available} }
@article{article, author = {Schwarz, A.M. and Hohenberger, G.M. and Grechenig, P. and Kerner, A. and G\"{a}nsslen, A. and Staresinic, M. and Bakota, B.}, year = {2021}, pages = {S58-S62}, DOI = {10.1016/j.injury.2020.07.039}, keywords = {none available}, journal = {Injury}, doi = {10.1016/j.injury.2020.07.039}, volume = {52}, issn = {0020-1383}, title = {The 2–2–2–20–20 concept for supraacetabular schanz screw insertion without additional radiography}, keyword = {none available} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font