Evaluation of screw placement in proximal humerus fractures regarding drilling manoeuvre and surgeon's experience


Hohenberger, Gloria Maria; Schwarz, Angelika Maria; Dauwe, Jan; Grechenig, Peter; Staresinic, Mario; Feigl, Georg; Bakota, Bore
Evaluation of screw placement in proximal humerus fractures regarding drilling manoeuvre and surgeon's experience // Injury, 52 (2021), S22-S26 doi:10.1016/j.injury.2020.02.120 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1275384 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Evaluation of screw placement in proximal humerus fractures regarding drilling manoeuvre and surgeon's experience

Autori
Hohenberger, Gloria Maria ; Schwarz, Angelika Maria ; Dauwe, Jan ; Grechenig, Peter ; Staresinic, Mario ; Feigl, Georg ; Bakota, Bore

Izvornik
Injury (0020-1383) 52 (2021); S22-S26

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Drilling ; PHILOS plate ; Proximal humeral fracture ; Proximal humeral plate osteosynthesis

Sažetak
Introduction: Following proximal humeral plate osteosynthesis, mechanical complication rates ranging up to 40% have been reported. The study aims to determine the influence of surgeons' experience and the technique of drilling on the complication rate. Materials and methods: The sample involved 45 cadaveric humeri. Six orthopaedic surgeons were divided into two groups with regard to their level of experience (novice versus expert group). On each humerus two different proximal humerus plates were applied. Drillings were performed either with a sharp or worn drill bit (to simulate either sharp or blunt drilling). The respective holes were drilled until the respective participant thought to have placed the drill bit subchondrally, followed by perforation of the cartilage of the humeral head. Both these values and cases of unintended penetration of the articular cavity were evaluated. Results: Fourteen holes (3.6%) were primary penetrated in the joint cavity in the worn-drill- bit-subgroup and 19 holes (5%) in the sharp-drill- bit-group. The latter had an average distance between the chosen subchondral position and the humeral articular surface of 8.3 mm and the worn- drill-bit-subgroup was at 10.6 mm. In the novice group 20 perforations (5.2%) of the joint space occurred and the mean interval between the chosen subchondral point and the humeral articular surface was 4.0 mm. The experienced surgeons showed a perforation rate of 3.4% and were at a mean of 14.9 mm. There were no significant differences regarding drilling manoeuvres and experience. Conclusion: Although our results are satisfactory, they can be traced back to the relatively high interval between the respective chosen position of the drill bit and the humeral articular surface which may not guarantee screw stability during ORIF of all fracture patterns.

Izvorni jezik
Engleski



POVEZANOST RADA


Profili:

Avatar Url Mario Starešinić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Hohenberger, Gloria Maria; Schwarz, Angelika Maria; Dauwe, Jan; Grechenig, Peter; Staresinic, Mario; Feigl, Georg; Bakota, Bore
Evaluation of screw placement in proximal humerus fractures regarding drilling manoeuvre and surgeon's experience // Injury, 52 (2021), S22-S26 doi:10.1016/j.injury.2020.02.120 (međunarodna recenzija, članak, znanstveni)
Hohenberger, G., Schwarz, A., Dauwe, J., Grechenig, P., Staresinic, M., Feigl, G. & Bakota, B. (2021) Evaluation of screw placement in proximal humerus fractures regarding drilling manoeuvre and surgeon's experience. Injury, 52, S22-S26 doi:10.1016/j.injury.2020.02.120.
@article{article, author = {Hohenberger, Gloria Maria and Schwarz, Angelika Maria and Dauwe, Jan and Grechenig, Peter and Staresinic, Mario and Feigl, Georg and Bakota, Bore}, year = {2021}, pages = {S22-S26}, DOI = {10.1016/j.injury.2020.02.120}, keywords = {Drilling, PHILOS plate, Proximal humeral fracture, Proximal humeral plate osteosynthesis}, journal = {Injury}, doi = {10.1016/j.injury.2020.02.120}, volume = {52}, issn = {0020-1383}, title = {Evaluation of screw placement in proximal humerus fractures regarding drilling manoeuvre and surgeon's experience}, keyword = {Drilling, PHILOS plate, Proximal humeral fracture, Proximal humeral plate osteosynthesis} }
@article{article, author = {Hohenberger, Gloria Maria and Schwarz, Angelika Maria and Dauwe, Jan and Grechenig, Peter and Staresinic, Mario and Feigl, Georg and Bakota, Bore}, year = {2021}, pages = {S22-S26}, DOI = {10.1016/j.injury.2020.02.120}, keywords = {Drilling, PHILOS plate, Proximal humeral fracture, Proximal humeral plate osteosynthesis}, journal = {Injury}, doi = {10.1016/j.injury.2020.02.120}, volume = {52}, issn = {0020-1383}, title = {Evaluation of screw placement in proximal humerus fractures regarding drilling manoeuvre and surgeon's experience}, keyword = {Drilling, PHILOS plate, Proximal humeral fracture, Proximal humeral plate osteosynthesis} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font