Pregled bibliografske jedinice broj: 1274236
Experimental Shielding Effectiveness Analysis of Impact Hexagonal Air-vent Distances on a Metal Enclosure
Experimental Shielding Effectiveness Analysis of Impact Hexagonal Air-vent Distances on a Metal Enclosure // ICEST 2018
Sozopol, Bugarska, 2018. str. 80-83 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1274236 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Experimental Shielding Effectiveness Analysis of Impact
Hexagonal Air-vent Distances on a Metal Enclosure
Autori
Nešić, Nataša ; Dončov, Nebojša ; Rupčić, Slavko ; Milovanović, Bratislav ; Mandrić-Radivojević, Vanja
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
ICEST 2018
/ - , 2018, 80-83
Skup
INTERNATIONAL SCIENTIFIC CONFERENCE ON INFORMATION, COMMUNICATION AND ENERGY SYSTEMS AND TECHNOLOGIES 2018
Mjesto i datum
Sozopol, Bugarska, 28.06.2018. - 30.06.2018
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Shielding effectiveness ; TLM hexagonal air-vent model ; TLM wire model ; Experimental analysis
Sažetak
In this paper the shielding effectiveness of metal enclosure with twelve hexagonal air-vents are experimentally studied. Therefore, two scenarios of hexagonal groups formed in 3x4 and 4x3 order are conducted. The experimental procedure is carried out in a semi-anechoic room. All measurement results are compared to the numerical ones obtained by TLM method with incorporated compact air-vent model and wire model.