Atmospheric Overvoltages Suppression: In Situ and Analytical Validation


Garma, Tonko; Šesnić, Silvestar; Alujević, Neven; Kovačić, Zvonko
Atmospheric Overvoltages Suppression: In Situ and Analytical Validation // IEEE transactions on electromagnetic compatibility, 65 (2023), 2; 486-495 doi:10.1109/TEMC.2022.3228596 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1267827 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Atmospheric Overvoltages Suppression: In Situ and Analytical Validation

Autori
Garma, Tonko ; Šesnić, Silvestar ; Alujević, Neven ; Kovačić, Zvonko

Izvornik
IEEE transactions on electromagnetic compatibility (0018-9375) 65 (2023), 2; 486-495

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Analytical modeling ; electromagnetic transients ; grounding electrode field measurements ; grounding system geometry ; lossy half-space ; surge pulse response ; time-domain analysis

Sažetak
This article deals with the issues arising from non-adequately designed grounding system of the telecommunication cell tower, in situ experimental investigations, novel system design, and consecutive verification as well as in-depth analysis based on the analytical model. The aforementioned surge pulse-based experiments confirmed the validity of the proposed modification in the grounding system geometry.As a measure of the novel solution’s effectiveness, the attenuation factor of the grounding system is used, defined as a ratio of the measured surge pulse peak at the electrode beginning and its end, with and without the novel modification. The value obtained with the modification active is 2.44, in comparison with the value of 1.12 for the bypassed modification. In order to obtain a more general set of conclusions, the modification is additionally verified by applying analytical modeling that enables the consideration of various parameters of the presented problem, in particular in terms of the various lightning pulses according to EN 62305 and for different electrode lengths. Presenting a continuation of the previously reported findings, this article exhibits that the analytical model can serve for engineering estimation of the grounding electrode response to various pulses and to design the optimal electrode geometry.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split,
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Neven Alujević (autor)

Avatar Url Silvestar Šesnić (autor)

Avatar Url Tonko Garma (autor)

Poveznice na cjeloviti tekst rada:

doi ieeexplore.ieee.org

Citiraj ovu publikaciju:

Garma, Tonko; Šesnić, Silvestar; Alujević, Neven; Kovačić, Zvonko
Atmospheric Overvoltages Suppression: In Situ and Analytical Validation // IEEE transactions on electromagnetic compatibility, 65 (2023), 2; 486-495 doi:10.1109/TEMC.2022.3228596 (međunarodna recenzija, članak, znanstveni)
Garma, T., Šesnić, S., Alujević, N. & Kovačić, Z. (2023) Atmospheric Overvoltages Suppression: In Situ and Analytical Validation. IEEE transactions on electromagnetic compatibility, 65 (2), 486-495 doi:10.1109/TEMC.2022.3228596.
@article{article, author = {Garma, Tonko and \v{S}esni\'{c}, Silvestar and Alujevi\'{c}, Neven and Kova\v{c}i\'{c}, Zvonko}, year = {2023}, pages = {486-495}, DOI = {10.1109/TEMC.2022.3228596}, keywords = {Analytical modeling, electromagnetic transients, grounding electrode field measurements, grounding system geometry, lossy half-space, surge pulse response, time-domain analysis}, journal = {IEEE transactions on electromagnetic compatibility}, doi = {10.1109/TEMC.2022.3228596}, volume = {65}, number = {2}, issn = {0018-9375}, title = {Atmospheric Overvoltages Suppression: In Situ and Analytical Validation}, keyword = {Analytical modeling, electromagnetic transients, grounding electrode field measurements, grounding system geometry, lossy half-space, surge pulse response, time-domain analysis} }
@article{article, author = {Garma, Tonko and \v{S}esni\'{c}, Silvestar and Alujevi\'{c}, Neven and Kova\v{c}i\'{c}, Zvonko}, year = {2023}, pages = {486-495}, DOI = {10.1109/TEMC.2022.3228596}, keywords = {Analytical modeling, electromagnetic transients, grounding electrode field measurements, grounding system geometry, lossy half-space, surge pulse response, time-domain analysis}, journal = {IEEE transactions on electromagnetic compatibility}, doi = {10.1109/TEMC.2022.3228596}, volume = {65}, number = {2}, issn = {0018-9375}, title = {Atmospheric Overvoltages Suppression: In Situ and Analytical Validation}, keyword = {Analytical modeling, electromagnetic transients, grounding electrode field measurements, grounding system geometry, lossy half-space, surge pulse response, time-domain analysis} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font