Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1265

Use of Results of Breakdown Voltage Tests for Determination of Life Parameters


Firinger, Vladimir
Use of Results of Breakdown Voltage Tests for Determination of Life Parameters // Proceedings: International Conference on Dielectrics and Insulation (I.C.D.I.), Budimpešta, Mađarska, 10-13.09. 1997. / Woynarovich, Gabor (ur.).
Budimpešta, Mađarska: Technical University of Budapest, 1997. str. 411-414 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 1265 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Use of Results of Breakdown Voltage Tests for Determination of Life Parameters

Autori
Firinger, Vladimir

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings: International Conference on Dielectrics and Insulation (I.C.D.I.), Budimpešta, Mađarska, 10-13.09. 1997. / Woynarovich, Gabor - : Technical University of Budapest, 1997, 411-414

Skup
International Conference on Dielectric and Insulation (I.C.D.I.)

Mjesto i datum
Budimpešta, Mađarska, 10.09.1997. - 13.09.1997

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
breakdown voltage test; insulating materials; insulating systems; thermal class; temperature index; rest of life; accuracy; measurement error; correction; reference value

Sažetak
Results of breakdown voltage tests do not depend only on properties of measured samples and standardised test conditions. They also depend on duration of breakdown voltage measurements. The report presents usage of reference values which eliminate influence of duration of breakdown voltage tests. The reference values bring the corrected results nearer to the physical property of breakdown strength and reduce the error of the measuring method. For computing life parameters, the accuracy of results of breakdown voltage measurements is very important.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
008004

Ustanove:
KONČAR - Institut za elektrotehniku d.d.

Profili:

Avatar Url Vladimir Firinger (autor)


Citiraj ovu publikaciju:

Firinger, Vladimir
Use of Results of Breakdown Voltage Tests for Determination of Life Parameters // Proceedings: International Conference on Dielectrics and Insulation (I.C.D.I.), Budimpešta, Mađarska, 10-13.09. 1997. / Woynarovich, Gabor (ur.).
Budimpešta, Mađarska: Technical University of Budapest, 1997. str. 411-414 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Firinger, V. (1997) Use of Results of Breakdown Voltage Tests for Determination of Life Parameters. U: Woynarovich, G. (ur.)Proceedings: International Conference on Dielectrics and Insulation (I.C.D.I.), Budimpešta, Mađarska, 10-13.09. 1997..
@article{article, author = {Firinger, Vladimir}, editor = {Woynarovich, G.}, year = {1997}, pages = {411-414}, keywords = {breakdown voltage test, insulating materials, insulating systems, thermal class, temperature index, rest of life, accuracy, measurement error, correction, reference value}, title = {Use of Results of Breakdown Voltage Tests for Determination of Life Parameters}, keyword = {breakdown voltage test, insulating materials, insulating systems, thermal class, temperature index, rest of life, accuracy, measurement error, correction, reference value}, publisher = {Technical University of Budapest}, publisherplace = {Budimpe\v{s}ta, Ma\djarska} }
@article{article, author = {Firinger, Vladimir}, editor = {Woynarovich, G.}, year = {1997}, pages = {411-414}, keywords = {breakdown voltage test, insulating materials, insulating systems, thermal class, temperature index, rest of life, accuracy, measurement error, correction, reference value}, title = {Use of Results of Breakdown Voltage Tests for Determination of Life Parameters}, keyword = {breakdown voltage test, insulating materials, insulating systems, thermal class, temperature index, rest of life, accuracy, measurement error, correction, reference value}, publisher = {Technical University of Budapest}, publisherplace = {Budimpe\v{s}ta, Ma\djarska} }