Pregled bibliografske jedinice broj: 1260488
Assessment of Reinforced Concrete Half Joint According to EN-1992-1-1
Assessment of Reinforced Concrete Half Joint According to EN-1992-1-1 // International Journal of Business and Technology: Vol. 5: Iss. 1, Article 3
Durres, Albanija, 2016. str. 1-7 doi:10.33107/ijbte.2016.5.1.03 (ostalo, podatak o recenziji nije dostupan, cjeloviti rad (in extenso), stručni)
CROSBI ID: 1260488 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Assessment of Reinforced Concrete Half Joint
According to EN-1992-1-1
Autori
Mulliqi, Xhemshir
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), stručni
Izvornik
International Journal of Business and Technology: Vol. 5: Iss. 1, Article 3
/ - , 2016, 1-7
Skup
International Journal of Business and Technology
Mjesto i datum
Durres, Albanija, 26.11.2016. - 30.11.2016
Vrsta sudjelovanja
Ostalo
Vrsta recenzije
Podatak o recenziji nije dostupan
Ključne riječi
Half-joint, Reinforcement, Strut-and-tie model, Tensile force
Sažetak
A half-joint is a particular type of RC structure .When using precast beams in reinforced concrete frame structures, dapped beams ends are often required in the bearing area to keep the floor structure as thin as possible. The arrangement and detailing of the reinforcement is an important factor in the performance of a half-joint. For pre- tensioned members, the prestressing force and tendons should be ignored, but for post-tensioned members the prestressing force should be considered as an external force acting on the half-joint. This paper aims to calculate dapped beam ends according to the EN 1992-1-1.
Izvorni jezik
Engleski