Pregled bibliografske jedinice broj: 1258629
Electrophysiological characteristics of supraventricular arrhythmias after cardiac transplantation – a case series
Electrophysiological characteristics of supraventricular arrhythmias after cardiac transplantation – a case series // Cardiologia Croatica, 16 (2021), 1-2
online, 2021. str. 13-13 doi:10.15836/ccar2021.13 (poster, domaća recenzija, sažetak, stručni)
CROSBI ID: 1258629 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Electrophysiological characteristics of supraventricular arrhythmias after cardiac transplantation – a case series
Autori
Prepolec, Ivan ; Pašara, Vedran ; Pezo-Nikolić, Borka ; Čikeš, Maja ; Skorić, Boško ; Puljević, Davor ; Miličić, Davor ; Velagić, Vedran
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni
Izvornik
Cardiologia Croatica, 16 (2021), 1-2
/ - , 2021, 13-13
Skup
13. kongres Hrvatskoga kardiološkog društva s međunarodnim sudjelovanjem
Mjesto i datum
Online, 10.12.2020. - 24.01.2021
Vrsta sudjelovanja
Poster
Vrsta recenzije
Domaća recenzija
Ključne riječi
supraventricular tachycardia ; supraventricular arrhythmia ; radiofrequency ablation ; cardiac transplantation
Sažetak
Supraventricular tachycardias (SVT) are increasingly recognized late complications after cardiac transplantation (CTX). The most commonly described arrhythmias include cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL), other macroreentrant atrial tachycardias (MRAT) and focal atrial tachycardias (AT). Although surgical substrate can be important, the effect of the surgical technique on the mechanism and the occurrence of arrhythmia remains unclear.1-3 We describe characteristics of CTX patients who presented with SVT for electrophysiological studies (EPS) at our centre from 2017 to 2020. Among 6 patients (mean age 48 ± 18 years, 4 of 6 were men), 2 presented during the first year after CTX, while 4 patients presented after a long follow-up (13.3 ± 2.8 years). Cardiac rejection was ruled out in all patients. In 3 patients significant graft vasculopathy was present. Initially, the conventional EPS was performed in all patients. In 5 cases, the initial diagnosis was CTI-dependent AFL and a successful radiofrequency ablation of CTI was performed. In one case, the arrhythmia was due to the non-CTIdependent MRAT and rate-control strategy was adopted. During the follow-up (29.2 ± 10.2 months), 3 patients remained without recurrences. In two patients early recurrence was noted (after 1 and 3 months) and a second EPS was performed (conventional or electroanatomical mapping) which demonstrated the multiple MRAT unsuitable for ablation. These patients were managed conservatively while one of them received second CTX due to advanced graft vasculopathy. During the follow-up one patient died due to graft rejection. In our group of patients typical AFL and other non-CTI-dependent MRAT were observed. In CTI-dependent AFL, conventional radiofrequency ablation was effective, while recurrences were more difficult to treat. Extensive scarring of the atria is the substrate for multiple MRAT circles that are not easily amenable with ablation.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb
Profili:
Maja Čikeš
(autor)
Borka Pezo Nikolić
(autor)
Vedran Pašara
(autor)
Vedran Velagić
(autor)
Boško Skorić
(autor)
Davor Puljević
(autor)
Ivan Prepolec
(autor)
Davor Miličić
(autor)