Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1257302

Post-Earthquake Condition Assessment and Seismic Upgrading Strategies for a Heritage-Protected School in Petrinja, Croatia


Salaman, Aida; Stepinac, Mislav; Matorić, Ivan; Klasić, Mija
Post-Earthquake Condition Assessment and Seismic Upgrading Strategies for a Heritage-Protected School in Petrinja, Croatia // Buildings, 12 (2022), 12; 2263, 28 doi:10.3390/buildings12122263 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1257302 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Post-Earthquake Condition Assessment and Seismic Upgrading Strategies for a Heritage-Protected School in Petrinja, Croatia

Autori
Salaman, Aida ; Stepinac, Mislav ; Matorić, Ivan ; Klasić, Mija

Izvornik
Buildings (2075-5309) 12 (2022), 12; 2263, 28

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Petrinja ; school ; earthquake ; FRP ; FRCM ; shotcrete ; renovation ; assessment ; 3Muri ; pushover

Sažetak
Following the Zagreb earthquake in March of 2020, a destructive 6.2 magnitude earthquake struck Croatia again in December of 2020. The Sisak-Moslavina county suffered the most severe consequences ; many historical and cultural buildings were badly damaged. In the education sector, 109 buildings were damaged. One such building is the case study of this research. The heritage-protected building of the First Primary School in Petrinja is an unreinforced masonry structure, constructed using traditional materials and building techniques. The historical background of the building and the results of the post-earthquake assessment are presented. A numerical calculation of three strengthening methods was performed in 3Muri software: FRCM, FRP, and shotcrete. Non-linear pushover analysis was performed for each model. Finally, the strengthening methods are compared based on the achieved earthquake capacity, cost, and environmental impact.

Izvorni jezik
Engleski

Znanstvena područja
Građevinarstvo



POVEZANOST RADA


Projekti:
UIP-2019-04-3749 - Procjena stanja i obnova postojećih građevina - Razvoj suvremenih metoda za zidane i drvene konstrukcije (ARES) (Stepinac, Mislav, HRZZ - 2019-04) ( CroRIS)

Ustanove:
Građevinski fakultet, Zagreb

Profili:

Avatar Url Mislav Stepinac (autor)

Poveznice na cjeloviti tekst rada:

doi www.mdpi.com

Citiraj ovu publikaciju:

Salaman, Aida; Stepinac, Mislav; Matorić, Ivan; Klasić, Mija
Post-Earthquake Condition Assessment and Seismic Upgrading Strategies for a Heritage-Protected School in Petrinja, Croatia // Buildings, 12 (2022), 12; 2263, 28 doi:10.3390/buildings12122263 (međunarodna recenzija, članak, znanstveni)
Salaman, A., Stepinac, M., Matorić, I. & Klasić, M. (2022) Post-Earthquake Condition Assessment and Seismic Upgrading Strategies for a Heritage-Protected School in Petrinja, Croatia. Buildings, 12 (12), 2263, 28 doi:10.3390/buildings12122263.
@article{article, author = {Salaman, Aida and Stepinac, Mislav and Matori\'{c}, Ivan and Klasi\'{c}, Mija}, year = {2022}, pages = {28}, DOI = {10.3390/buildings12122263}, chapter = {2263}, keywords = {Petrinja, school, earthquake, FRP, FRCM, shotcrete, renovation, assessment, 3Muri, pushover}, journal = {Buildings}, doi = {10.3390/buildings12122263}, volume = {12}, number = {12}, issn = {2075-5309}, title = {Post-Earthquake Condition Assessment and Seismic Upgrading Strategies for a Heritage-Protected School in Petrinja, Croatia}, keyword = {Petrinja, school, earthquake, FRP, FRCM, shotcrete, renovation, assessment, 3Muri, pushover}, chapternumber = {2263} }
@article{article, author = {Salaman, Aida and Stepinac, Mislav and Matori\'{c}, Ivan and Klasi\'{c}, Mija}, year = {2022}, pages = {28}, DOI = {10.3390/buildings12122263}, chapter = {2263}, keywords = {Petrinja, school, earthquake, FRP, FRCM, shotcrete, renovation, assessment, 3Muri, pushover}, journal = {Buildings}, doi = {10.3390/buildings12122263}, volume = {12}, number = {12}, issn = {2075-5309}, title = {Post-Earthquake Condition Assessment and Seismic Upgrading Strategies for a Heritage-Protected School in Petrinja, Croatia}, keyword = {Petrinja, school, earthquake, FRP, FRCM, shotcrete, renovation, assessment, 3Muri, pushover}, chapternumber = {2263} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • Social Science Citation Index (SSCI)
    • SCI-EXP, SSCI i/ili A&HCI
    • Emerging Sources Citation Index (ESCI)
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font