Diagnostic accuracy of non-invasive tear film break-up time assessed by the simple manual interferometric device
Diagnostic accuracy of non-invasive tear film break-up time assessed by the simple manual interferometric device // Contact Lens & Anterior Eye, 13 (2022), 101776, 6 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1254887 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Diagnostic accuracy of non-invasive tear film
break-up time assessed by the simple manual
interferometric device
Autori
Sania Vidas Pauk, Igor Petriček, Martina Tomić, Tomislav Bulum Sonja Jandroković Maja Pauk Gulić Miro Kalauz Dina Lešin Gaćina
Izvornik
Contact Lens & Anterior Eye (1367-0484) 13
(2022);
101776, 6
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Tears, Dry eye disease, Non-invasive tear break-up time, Diagnostic tests, Specificity, Sensitivity, Area under the curve
Sažetak
Aim To determine the diagnostic accuracy of non- invasive tear film break-up time (NIBUT) measured by the handheld lipid layer examination instrument. Methods 108 patients were enrolled in this cross- sectional study and divided into two groups: patients with dry eye (n = 57) categorized by the presence of dry eye symptoms obtained by Schein Questionnaire and minimally-one objective dry eye sign (tear film break-up time <10 s or corneal, conjunctival and lid margin fluorescein staining), and healthy subjects (n = 51). Results Dry eye subjects had significantly shorter NIBUT than healthy subjects (6 s vs 20 s, p < 0.001). Logistic regression analysis showed that shorter NIBUT values were excellent indicators of dry eye disease (p < 0.001), with consistency and no significant difference between measurements, even after standardizing the results for age and sex. NIBUT cut-off point to distinguish dry eye from healthy subjects was 12 s (sensitivity 90.2 %, specificity 88.5 %, PPV 92.5 %, NPV 85.2 %, LR +7.82, LR− 0.11, DOR 70.92, DE 89.6 %). Good, but lower accuracy was observed at cut-off value of 10 s (sensitivity 87.8 %, specificity 88.5 %, PPV 92.3 %, NPV 82.1 %, LR+ 7.61, LR− 0.14, DOR 55.2, DE 88.1 %). The area under the ROC curve (AUC) of 0.944 classified NIBUT as a diagnostic test with very high accuracy. Conclusion This study showed a high diagnostic accuracy of NIBUT measured by the handheld lipid layer examination instrument. This simple, reliable, objective and available instrument might regularly take place in routine, standard dry eye diagnostic and can be used by almost every eye specialist.
Izvorni jezik
Engleski
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb
Profili:
Miro Kalauz
(autor)
Igor Petriček
(autor)
Dina Lešin
(autor)
Tomislav Bulum
(autor)
Martina Tomić
(autor)
Sonja Jandroković
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE