Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method


Lapaš Barišić, Matea; Sarajlija, Hrvoje; Klarić, Eva; Knežević, Alena; Sabol, Ivan; Pandurić, Vlatko
Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method // Polymers, 15 (2023), 3; 627, 16 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1254095 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method

Autori
Lapaš Barišić, Matea ; Sarajlija, Hrvoje ; Klarić, Eva ; Knežević, Alena ; Sabol, Ivan ; Pandurić, Vlatko

Izvornik
Polymers (2073-4360) 15 (2023), 3; 627, 16

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
bulk-fill composites ; dental composites ; elution ; liquid chromatography coupled with triple quadrupole tandem mass spectrometry (LC-MS/MS) ; residual monomer.

Sažetak
The aim of this study was to investigate leachable components (monomers) in high and low viscosity dental bulk-fill resin composites and conventional resin composite materials after polymerization. Six bulk-fill and six conventional dental resin composite materials were used in this study. The samples of each material (three sets of triplicates) were cured for 20 s with irradiance of 1200 mW/cm2 with a LED curing unit and immersed in a 75% ethanol solution at 37 °C. The eluates from each triplicate set were analyzed after 24 h, 7 days or 28 days using liquid chromatography coupled with triple quadrupole tandem mass spectrometry (LC-MS/MS). Detectable amounts of 2- Hydroxyethyl methacrylate (HEMA) were found in both Gradia materials and the amount observed across different time points was statistically different (p ˂ 0.05), with the amount in solution increasing for Gradia and decreasing for Gradia Direct flo. Bisphenol A diglycidildimethacrylate (BIS GMA) was found in Filtek and Tetric materials. Triethylene glycol dimethacrylate (TEGDMA) was detected in all materials. On the other hand, there were no statistically significant differences in the amounts of TEGDMA detected across different time points in either of the tested materials. Monomers HEMA, TEGDMA, 4- dimethylaminobenzoic acid ethyl ester (DMA BEE) and BIS GMA in bulk-fill and conventional composites (high and low viscosity) can be eluted after polymerization. The good selection of composite material and proper handling, the following of the manufacturer's instructions for polymerization and the use of finishing and polishing procedures may reduce the elution of the unpolymerized monomers> responsible for the possible allergic and genotoxic potential of dental resin composites.

Izvorni jezik
Engleski

Znanstvena područja
Dentalna medicina



POVEZANOST RADA


Ustanove:
Stomatološki fakultet, Zagreb,
Institut "Ruđer Bošković", Zagreb,
Centar za forenzična ispitivanja, istraživanja i vještačenja "Ivan Vučetić"

Poveznice na cjeloviti tekst rada:

www.mdpi.com

Citiraj ovu publikaciju:

Lapaš Barišić, Matea; Sarajlija, Hrvoje; Klarić, Eva; Knežević, Alena; Sabol, Ivan; Pandurić, Vlatko
Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method // Polymers, 15 (2023), 3; 627, 16 (međunarodna recenzija, članak, znanstveni)
Lapaš Barišić, M., Sarajlija, H., Klarić, E., Knežević, A., Sabol, I. & Pandurić, V. (2023) Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method. Polymers, 15 (3), 627, 16.
@article{article, author = {Lapa\v{s} Bari\v{s}i\'{c}, Matea and Sarajlija, Hrvoje and Klari\'{c}, Eva and Kne\v{z}evi\'{c}, Alena and Sabol, Ivan and Panduri\'{c}, Vlatko}, year = {2023}, pages = {16}, chapter = {627}, keywords = {bulk-fill composites, dental composites, elution, liquid chromatography coupled with triple quadrupole tandem mass spectrometry (LC-MS/MS), residual monomer.}, journal = {Polymers}, volume = {15}, number = {3}, issn = {2073-4360}, title = {Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method}, keyword = {bulk-fill composites, dental composites, elution, liquid chromatography coupled with triple quadrupole tandem mass spectrometry (LC-MS/MS), residual monomer.}, chapternumber = {627} }
@article{article, author = {Lapa\v{s} Bari\v{s}i\'{c}, Matea and Sarajlija, Hrvoje and Klari\'{c}, Eva and Kne\v{z}evi\'{c}, Alena and Sabol, Ivan and Panduri\'{c}, Vlatko}, year = {2023}, pages = {16}, chapter = {627}, keywords = {bulk-fill composites, dental composites, elution, liquid chromatography coupled with triple quadrupole tandem mass spectrometry (LC-MS/MS), residual monomer.}, journal = {Polymers}, volume = {15}, number = {3}, issn = {2073-4360}, title = {Detection of Leachable Components from Conventional and Dental Bulk-Fill Resin Composites (High and Low Viscosity) Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method}, keyword = {bulk-fill composites, dental composites, elution, liquid chromatography coupled with triple quadrupole tandem mass spectrometry (LC-MS/MS), residual monomer.}, chapternumber = {627} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus





Contrast
Increase Font
Decrease Font
Dyslexic Font